MENU
Humidifier
SYSTEM SETUP
Dehumidifier
OUTDOOR SENSOR
RESIDUAL COOL
BALANCE POINT
TEMPERATURE CONTROL MODE
WALL INSULATION
DEADBAND
SMOOTH SETBACK RECOVERY
OFFSET
Table 5. Advanced Settings
SETTING (default is bold)
Not Installed
Humidification
Not Installed
Humiditrol - Min
Humiditrol - Mid
Humiditrol - Max
Auxiliary Dehumidifier
Yes or No
0, 30, 60, 90, 120 seconds, -300 (5 min delayed)
Disabled or Enabled
Normal and Comfort
Poor, Average and Good
3°F Adjustable (3 to 8°F)
Enabled or Disabled
Temperature Offset - 0°F
Humidity Offset - 0%
16
Notes:
These options only appear under System
Setup if the H/D and ACC terminals have been
enabled for the specific type of accessory.
Go to Terminal Settings to enabled attached
accessory for the specific terminal being used.
Required for high and low balance points
option.
When enabled:
Low Balance Point: 25°F (-20 to 72°F)
High Balance Point: 50°F
(-17 to 75°F)
Adjustable (-5 to 5°F)
Adjustable (-10 to 10%)