Mode Description - Toshiba TOSVERT VF-S15 Instruction Manual

Functions for lift application
Hide thumbs Also See for TOSVERT VF-S15:
Table of Contents

Advertisement

3.2 Mode description

The light-load high-speed operation includes the modes below:
Each mode can be set by the light-load high-speed operation selection (f328).
Title/function
0: Disabled
1:High-speed operation speed set automatically
f328
(Power running at F command: Increase)
Light-load
2:High-speed operation speed set automatically
high-speed
(Power running at R command: Increase)
operation
3:High-speed operation speed set with f330
selection
(Power running at F command: Increase)
4:High-speed operation speed set with f330
(Power running at R command: Increase)
Example: If automatic setting mode of high-speed operation speed is used,
set f328 to 1 for F (forward command): Up
set f328 to 2 for R (reverse command): Up
Note: Light load output and Heavy load output conditions of output terminal functions are different
according to f328 setting.
1) f328 (Light-load high-speed operation selection) =0
Light load output (Function No. 106/107):
ON: The absolute value of the detected torque is under the absolute value of f335
(Switching load torque during power running)
Light load output (Function No. 164/165):
ON: The absolute value of the detected torque is under the absolute value of f335
(Switching load torque during power running)
Heavy load output (Function No. 108/109):
ON: The absolute value of the detected torque is the absolute value of f337 (Heavy-load
torque during constant power running) or more
Note) Function No. 106/107 and No.164/165 are same action when f328=0. Each action is
different when f328 setting is not 0.
f337
f335
f335
f337
Function No.106
Function No.108
Function No.164
Default setting
Torque
0%
Action
Light-load high-speed operation
disabled.
When inverter judges to be light-load,
the high-speed operation frequency
is automatically set according to a
detected torque.
When inverter judges to be light-load,
the operation is set to the automatic
light-load high-speed operation
frequency (f330).
E6581871