Make Electrical Connections - Whirlpool Gold WFD193 Installation Instructions Manual

93 percent convertible multispeed gas furnace
Hide thumbs Also See for Gold WFD193:
Table of Contents

Advertisement

Upright Installations
Depending on the installation and/or customer preference, filters
can be installed in the central return register or a side panel
external filter rack kit (upflows). As an alternative a media air filter
or electronic air cleaner can be used as the requested filter.
Filter Locations—Possible Upright Upflow
A
B
A. Central return grille
B. Filter
Filter Locations—Possible Upright Counterflow
A
B
F
E
D
A. Filter access door
B. Filter
C. Central return grille
Horizontal Installations
Filters must be installed in either the central return register or in
the return air ductwork.
C
B
D
C. Airflow
D. Side return external filter rack kit
(either side)
B
C
D. Airflow
E. Filter support bracket (provided)
F. Return duct
To avoid the risk of electrical shock, wiring to the unit
must be polarized and grounded.
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage,
personal injury or death.
Edges of sheet metal holes may be sharp. Use gloves as
a precaution when removing hole plugs.
B
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Thermostat
NOTE: Wire routing must not interfere with circulator blower
operation, filter removal, or routine maintenance.
Low voltage connections can be made through either the right-
hand or left-hand side panel. Thermostat wiring entrance holes
are located in the lower compartment. Refer to "Thermostat
Diagram" for thermostat connections to the integrated control
module terminal strip.
Thermostat Diagram
A
W
A. Heating room thermostat
B. Furnace
This furnace is equipped with a 40 VA transformer to facilitate use
with most cooling equipment. Consult the wiring diagram located
on the blower compartment door for further details of 115-volt
and 24-volt wiring.
1. Disconnect power.
2. Remove the screw from the furnace electrical connection
box.

Make Electrical Connections

WARNING
Goodman 70
WARNING
HIGH VOLTAGE!
Goodman 6
WARNING
Goodman 56
CAUTION
Goodman 59
B
Y
C
W
Y
W
R
R
R
G
G
C
C. Heating and cooling room thermostat
D. Remote condensing unit
B
Y
D
W
Y
R
C
G
C
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gold wpio-299f

Table of Contents