Connect The Cable To The Outdoor Unit - Panasonic CU-4E27PBE Service Manual

Outdoor unit
Hide thumbs Also See for CU-4E27PBE:
Table of Contents

Advertisement

10.5 Connect The Cable To The Outdoor Unit

1. Remove the particular plate from the unit by
loosening two screws.
2. Cable connection to the power supply through
isolating Devices (Disconnecting means).
Connect approved type polychloroprene
o
sheathed power supply cord
CU-4E27***(3 x 2.5 mm²), CU-5E34***
(3 x 4.0 mm²) 245 IEC 57 type
designation or heavier cord to the
terminal board, and connect the others
end of the cord to Isolating Devices
(Disconnecting means).
3. Connection cable between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 4 x 1.5 mm
cord, type designation 245 IEC 57 or heavier
cord.
5. For wire stripping and connection requirement, refer to the diagram below.
6. Secure the power supply cord and connecting cables onto the control board with the holder.
7. Attach the control board cover back to the original position with screw.
AMP Air Conditioning
4. Connect the power supply cord and
2
flexible
32
connection cable between indoor unit and
outdoor unit according to the diagram as
shown.
www.ampair.co.uk | sales@ampair.co.uk

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-5e34pbe