Programming The Thermostat; Operating Mode; Manual Mode - Conrad Electronic 61 06 29 Operating Instructions Manual

Room thermostat with day program
Table of Contents

Advertisement

Available languages

Available languages

Terminal (2) is the switch contact (AC 230V/ 50-60HZ / max. load: 3,600 W, Ohm resistive
load). It is possible to connect a heater or an electric floor heater here.
Terminal (3) if not already already done, the supplied temperaturesensor is to be connected
here. The temperature sensor, however, must be placed outside the flush-mount-
ed socket.
• After carrying out the electric connection, press the thermostat into the flush-mounted socket.
Since the thermostat does not have a fastening clamp on the left and right, e. g. like flush-
mounted sockets or flush-mounted light switches, the thermostat must be fastened in the
flush-mounted socket with two screws.

Programming the Thermostat

If the switch (11) is set to the „OFF" position, the LED switches off and there is no display. In
„ON" position, the LED blinks and you can see the settings in the display. Now switch on the
thermostat!
Please note that if the keys (14), (15) and (16) are not pressed within
about 15 seconds, the previous screen is shown in the display.
1. Operating mode (settings)
With the keys (14), (15) and (16) you can choose between the modes „manual mode", „mode to
set the time" and „automatic mode".
(1) Press button (15)! On the display, the symbols (8) and (9) flash.
(2) Now the corresponding modes can be selected with the keys (14) and (16). The corre-
sponding symbol flashes in the mode that has now been selected.

Manual Mode.

Symbol (13) flashes
2. Manual Mode
With this function the automatic mode is deactivated. The connected consumer load is switched
on and remains activated until the preset time is reached.
Mode to set the time
Symbol (9) flashes
Automatic Mode
Symbols (8) and (9) flash
17