AC-7000 User guide
-Inside Open NO or Inside Open NC: When the exit button was connected
-Fire detection NO or Fire detection NC: When the fire detection sensor is
connected.
-Panic detection NO or panic detection NC‟: When the panic situation detection
sensor is connected.
-Emergency detection NO or emergency detection NC‟: When the emergency
situation detection sensor is connected.
-> Set NO/NC according to the state of pin input in detection
▶Warn door open (sec)
This function alarms when set time for door open (5~30 seconds) is passed with the
opened door.
If it is set [0], no alarm is ringing, and though you set [01~04], the alarm will ring after 5
seconds.
This function enables the appropriate action to close the door when someone could know
that the door is not closed properly by alarming when the door is not closed for specific
time.
To use the function, the lock must be able to be monitored if it is opened or closed, and
the monitoring pin of the lock also should be connected with M0.
previous M0 also should be set [Door open NO] or [Door open NC].
▶Terminal disassemble warning sound
If it is checked(
disassembled.
Click [OK] button to apply the set value, and click [BACK] button to cancel and return.

3.7.4. Lock settings

If you select the [Terminal]->[Lock settings] in the main menu, the following
windows appears.
㈜Union Community / Hyundai Topics building 5
Songpa-gu, Seoul, Korea (138-050)
Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@unioncomm.co.kr
http://www.unioncomm.co.kr
), a warning sound will be played when the terminal is