Download Print this page
Siemens 2000 Series Quick Reference Manual

Siemens 2000 Series Quick Reference Manual

Room temperature sensors, tec, standard design and semi-flush mount

Advertisement

Quick Links

Series 2000 (Interactive) Room
Temperature Sensors, TEC, Standard
Design and Semi-Flush Mount
Overview
For high-end Terminal Equipment Controller (TEC)
applications, these sensors allow users to view and
adjust points in the controller using the sensor buttons
and digital display.
A user-programmable display allows the simultaneous
monitoring of the temperature, a user-selected point
and day/night operation status.
Features
User-programmable two-line liquid crystal
display
Simultaneous display of temperature, a user-
selected point, and day/night operation status
Backward compatibility with all TECs, including
PTECs.
Hardware-protected security
Standard RJ-11 terminated cable
No separate power source requirement
Digital (error-free) setpoint adjustment
Product Numbers
Description
Desert Beige
TEC Sensors
540-650A
TEC Sensors with
540-652A
Fan-Speed
Control (Momentary
contact)
TEC Semi-Flush
Mount
Accessories
Description
Passkey
Computer cable
Item Number 129-363, Rev. DA
Product Number
White
540-650B
540-652B
QAA1280FWSC
Product Number
544-643A
540-143
Quick Reference Guide
Applications
Operating rooms
Laboratories
Isolation rooms, with pressurization as the
critical point
Other difficult control spaces
Executive suites and other high-profile areas
Operation
Buttons
The function of each button varies, depending on the
current screen. For detailed instructions, see Operating
Instructions.
Operation modes
Figure 1. Operation Modes.
Document No. 129-363
May 13, 2015
Page 1 of 3

Advertisement

loading

Summary of Contents for Siemens 2000 Series

  • Page 1 Quick Reference Guide Document No. 129-363 May 13, 2015 Series 2000 (Interactive) Room Temperature Sensors, TEC, Standard Design and Semi-Flush Mount Overview For high-end Terminal Equipment Controller (TEC) applications, these sensors allow users to view and adjust points in the controller using the sensor buttons and digital display.
  • Page 2: Specifications

    To exit: Press or wait five seconds. (CIS), connect a computer-compatible cable (see Accessories) from a laptop to the sensor MMI port at the bottom of the sensor. This puts the sensor in laptop Page 2 of 3 Siemens Industry, Inc.
  • Page 3 Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. © 2015 Siemens Industry, Inc. Siemens Industry, Inc.