Detailed Description - FATEK FBs-1HLC Operation Manuals

Precision load cell module
Hide thumbs Also See for FBs-1HLC:
Table of Contents

Advertisement

Status/Settings register
Address
402305
AD internal value
402307
Display value
SPAN calibration
402567
402561
Max. weight
Calibration error
401793
message
402049 AD sampling frequency 0=100、1=50、2=25、3=12.5、4=6.25Hz
402052
Min. scale

1.5.2 Detailed description

Status/Control bit
Address
Name
000002
Overload flag
Display gross
000005
weight flag
Display net weight
000006
000007
Zero-point flag
000008
Unstable flag
000257
Adjust to zero
000258
Deduction
000263
Clear deduction
Zero-point
000513
calibration input
Full-span calibration
000514
000773
Save EEP
Name
weight
Flag ON when the measured weight is higher than the max. weight
Displayed measurement value includes package weight
Displayed measurement value is actual weight
flag
Gross weight is 0 when=1
Conditions of unstable tracking time and unstable tracking area may be set for the
devices maintaining stable values
Function to set or adjust the displayed value to zero when there is no load
when=1
Deduce the package weight of the load on the tray when=1
Clear the package weight deduction and display gross weight when=1
Zero-point button to be set during calibration when=1
SPAN weight button to be set during calibration when=1 (SPAN calibration weight
input
should be set first)
Save settings in EEPROM and automatically read previously saved settings at
power-on when=1
Settings
0~3
1,2,5,10,20,50
Description
7
Length
R/W
Word
R
2Word
R
2Word
R
2Word
R/W
Word
R/W
Word
R/W
Word
R/W

Hide quick links:

Advertisement

Table of Contents
loading