43
WFMC/WFXD Service Tips
WFMC/WFXD Service Tips
HINT: Heater can be removed
from the back of the tub –
remove
rear
panel
access.
R020031E
for
10ºC (50ºF): 36 – 44kW
20ºC (68ºF): 22.8 – 27.4kW
30ºC (86ºF): 14.8 – 17.5kW
40ºC (104ºF): 9.8 – 11.5kW
50ºC (122ºF): 6.6 – 7.7kW
60ºC (140ºF): 4.6 – 5.3kW
66ºC (151ºF): 3.73 – 4.29kW
73ºC (163ºF): 2.94 – 3.36kW
NTC
86ºC (187ºF): 1.93 – 2.19kW
/
–
NTC & Heater
–
NTC & Heater
HINT: NTC connector is latched
– carefully pry latch with small
blade screwdriver to remove it.
2nd Edition/Revision 0 (4/28/04)