Indoor Unit - Mitsubishi Electric MSZ-AP25VG Service Manual

Split-type air conditioner
Hide thumbs Also See for MSZ-AP25VG:
Table of Contents

Advertisement

10-3. INSTRUCTION OF TROUBLESHOOTING
1. Check of the unit.
Start
Indoor unit oper-
ates.
Outdoor unit
does not operate.
Outdoor unit
Outdoor unit
operates only
does not
in Test Run
operate even
operation.
in Test Run
operation.
Check room
Refer to "How
temperature
to check
thermistor.
inverter/com-
Refer to 10-7.
pressor".
"Test point
diagram and
voltage".
Upper lamp
Upper lamp
Flash on and
2-time fl ash
off at 0.5-sec-
Cause:
ond intervals

Indoor unit

Cause:
• Trouble
Indoor/Outdoor
of room
unit
temperature
• Miswiring or
/ indoor coil
trouble of
thermistor
serial signal
Refer to
Check room
10-6. "How
temperature
to check mis-
thermistor
wiring and
and indoor
serial signal
coil thermis-
error".
tor. Refer to
10-7."Test
point diagram
and voltage".
OBH788
Indoor unit operates.
Indoor unit does
Outdoor unit does
not receive the
not operate normally.
signal from re-
mote controller.
Indoor unit
Unit does not
operates, when
operate nor-
EMERGENCY
mal operation
OPERATION
in COOL or
switch is pressed.
HEAT mode.
Refer to
Refer to 10-6.
"Check of R.V.
"Check of remote
coil".
controller and
indoor electronic
control P.C. board".
Upper lamp
Upper lamp
4-time fl ash
3-time fl ash
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble
• Trouble of
of indoor
indoor fan
unit control
motor
system
Refer to
Replace the
10-6.
indoor elec-
"Check of
tronic control
indoor fan
P.C. board.
motor".
OPERATION INDICATOR
lamp on the indoor unit is
fl ashing ON and OFF.
Indoor unit does
not operate, when
EMERGENCY
OPERATION
switch is pressed.
1. Check indoor/out-
door connecting wire.
(Check if the power is
supplied to the indoor
unit.)
2. Refer to 10-6.
"Check
of indoor P.C. board
and indoor fan motor".
Upper lamp
Upper lamp
6-time fl ash
5-time fl ash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Outdoor
thermistor in
power sys-
outdoor unit
tem abnor-
mality
Refer to
Refer to
"How to
"Check of
check
outdoor ther-
inverter/com-
mistors".
pressor".
22
NOTE: The indoor unit does not
operate by smartphone,
refer to 10-3.2."Check of
Wi-Fi Interface".
"Test Run operation" means the
operation within 30 minutes af-
ter EMERGENCY OPERATION
switch is pressed.
If blinking of OPERATION INDI-
CATOR lamp cannot be checked,
it can be checked with failure
mode recall function.
Refer to outdoor unit service manual.
Upper lamp
Upper lamp
7-time fl ash
14-time fl ash
Cause:
or more
Outdoor unit
Cause:
• Trouble of
Outdoor unit
outdoor con-
• Other ab-
trol system
normality
Replace the
Check "Flow
inverter P.C.
chart of the
board or
detailed
the outdoor
outdoor unit
electronic
failure mode
control P.C.
recall func-
board.
tion."