LED Display
The following LeD displays are available:
• Green LED (4) marked POWER. This LED will be lighted when the inverter is
in ON condition. When the inverter is in OFF condition, this LED will not be
lighted. This LeD shows that DC input is available to the inverter and that
the input section of the inverter is operating normally
• Red LED (2) marked OVER LOAD. When lighted, it indicates that the AC
output of the inverter has been shut down due to over load
• Red LED (3) marked OVER TEMP. When lighted, it indicates that the AC
output of the inverter has been shut down due to over temperature
ON/OFF Control
oN/off Push button (1) is used to switch oN and switch off the inverter.
Pinout Of Rj-12 / Rj-25 Modular jack
The pinout of the RJ-12 / RJ-25 Modular Jack (5) at the back of the unit is given
at fig. 2 below:
Fig. 2 Remote Control RC-15A - Pinout of Modular Jack RJ-12 / RJ-25
The standard numbering system of the pins of a Modular Jack, when looking
into the Jack, is from left to right. As the conductors of the cable are cross-
connected (rolled-over), the pinouts at the Modular Jack in the inverter will
be a mirror image of the pinout of the Modular Jack in the Remote Control as
shown below:
Pinout of Modular jack on
the Remote Control
1
2
3
4
5
6
1. As shown in Figure 2
2. Mirror image of Remote Control Jack due to crossed-over /rolled over connection of conductors.
1
2
3
Figure 2 Remote Control RC-15A; Pintout of Modular Jack RJ-12 / RJ-25
1
LED - "OVER LOAD"
Ground / Common
LED - "POWER ON"
LED - "OVER TEMP"
LEGEND
1.
LED - "Over Load"
4
5
6
2.
Toggle
3.
Ground
4.
Vbattery
5.
LED - "Power ON"
6.
LED - "Over Temp"
Signal
Toggle
Vbattery
Pinout of Modular
jack on the inverter
6
5
4
3
2