Actual Wiring Diagram (In Case Of 4.0L) - Panasonic NC-HU301P Service Manual

Electric thermo pot
Hide thumbs Also See for NC-HU301P:
Table of Contents

Advertisement

NC-HU301P, NC-HU401P

5.3. Actual Wiring Diagram (in case of 4.0L)

Return to original wiring after repair.
Lead wires touch to the surface of
parts, and may cause fault or
power shock.
Boiling Heater (990.9W)
Peg Frame Comp.
AC 240V
Funen Tube
Lead Wire Assy A (White)
Motor Tube (Yellow)
Pump Comp.
Caution
Keep Warm Heater (133.3W)
Funen-Ben
Thermal fuse (Indication: 157°C)
Lead Wire Assy B
Thermal fuse Comp.
Lead Wire Assy C
Lead Wire Assy E
(12 cores)
Ceramic Terminal
Earth Wire Assy (Green)
Lead Wire H (Blue)
Lead Wire M
Thermistor Assy
Marking colur: Light Green
— 35 —
Lead Wire Assy D
Lead Wire K
Lead Wire J
Control Unit A
Control Unit B