4.2.4 The cause and solution of the malfunction

1) Fuser Error
Description: A message "Open fuser/Over heat/Low heat' is displayed in a LCD panel.
1. Check whether a thermostat,
AC wire, and heat lamp are
thermistor is open or not.
3. Heat lamp ON/OFF test
4. It could not operate
due to a gear of a fuser is melted.
Samsung Electronics
open or not.
2. Check whether a
Adjustment and Troubleshooting
Replace the fuser if a thermostat
is open.
Replace the fuser if a thermistor
sensor is located deep inside of
a sponge.
Check whether the overheat
mode circuit operates normally
or not.
Replace the fuser.