Removal:
1-
Remove the free arm extension table, tension assembly dial, the knobs of the zig-zag and
needle position levers, all covers (face plate, rear, bottom bed and front) and head end
assembly.
2- Loosen screw (A) sufficiently to clear the recess on the thread take-up stud (C).
3- Slide take-up lever assembly (B), take-up stud (C) and needle bar connecting link (D).
Replacement:
1-
Replacement is the same as removal in reverse order. Make sure that stud (C) is firmly
located against link (D).
2- Adjust needle
location in the needle plate slot and needle to hook
to 75)
3- Check hook timing and needle bar height and presser bar height and adjust if necessary. (See
pages 64-65 and 88-89)
4- Adjust presser bar alignment and height. (See pages 84-85)
Rev. n .
o
MAY/00
Take-up Lever Assembly and
Needle Bar Connecting Link
relationship. (See pages 70
20