Air Filter - Generac Power Systems iQ2000 Owner's Manual

Hide thumbs Also See for iQ2000:
Table of Contents

Advertisement

Available languages

Available languages

Inspect Engine Oil Level
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so
could result in death or serious injury.
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill.
3. See
Figure
4-1. Remove oil fill cap and
wipe dipstick clean.
Figure 4-1. Engine Oil Fill
4. Screw dipstick into filler neck. Remove
dipstick and verify oil level is within safe
operating range. See
Figure 4-2. Safe Operating Range
5. Screw funnel into oil fill opening. Add rec-
ommended engine oil as necessary.
6. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
Change Engine Oil
Accidental start-up. Disconnect spark plug wires
when working on unit. Failure to do so could result
in death or serious injury.
When using generator under extreme, dirty,
dusty conditions, or in extremely hot weather,
change oil more frequently.
NOTE: Don't pollute. Conserve resources.
Return used oil to collection centers.
Owner's Manual for Portable Generator
Figure
4-2.
WARNING
Change oil while engine is still warm from run-
ning, as follows:
1. Place generator on a level surface.
2. Disconnect the spark plug wire from the
spark plug and place the wire where it
cannot contact spark plug.
(000139)
3. Clean area around oil fill, and oil drain
plug.
4. Remove oil fill cap. Screw funnel into oil fill
opening. See
5. Tip unit and drain oil completely into a suit-
able container.
6. Slowly pour oil into oil fill opening until oil
level is between L and H marks on dip-
stick. DO NOT overfill.
7. Install oil fill cap, and finger tighten.
8. Wipe up any spilled oil.
9. Properly dispose of oil in accordance with
all applicable regulations.
000804
Figure 4-3. Oil Fill Opening With Funnel

Air Filter

Engine will not run properly and may be dam-
aged if run with a dirty air filter. Service air fil-
ter more frequently in dirty or dusty conditions.
To service air filter:
1. See
service door (A).
000116
2. Unscrew bolt (B) and remove air filter
cover (C).
3. Wash filter (D) in soapy water. Squeeze
dry in clean cloth (DO NOT TWIST).
4. Clean air filter cover before re-installing it.
NOTE: To order a new air filter, contact the
nearest authorized service center at 1-888-
GENERAC (1-888-436-3722).
(000141)
Figure
4-3.
Figure
4-4. Turn knob and remove
A
A
C
D
B
Figure 4-4. Air Filter Assembly
000822
000666
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents