5. INSTALLATION AND CONNECTION

5.1. Location, assembly and ventilation

The eMIMO1616 has been specially designed for incorporation within a 19" rack,
occupying 2 U's.
It is very important that, as a heat generating element, the unit is not completely
enclosed or exposed to extreme temperatures. The passage of fresh air through the
ventilation holes on the chassis should be ensured, by leaving at least 1 U free
between each unit and those installed above and below on the rack.
If the installation includes various pieces of equipment on the same rack, or is
within a cabinet with doors, then the provision of upward forced ventilation,
through the fitting of fans on the lower and upper extremes, is highly
recommended. The upward ventilation flow will improve the dissipation of heat
generated within.

5.2. Connection to the mains supply and switching on

The eMIMO1616 is powered by an AC voltage of 90 to 264V at 47 to 63Hz. The unit
features an overdimensioned power supply unit capable of adapting to the supply
voltage in any country in the world without the need for adjustment.
The on/off switch for the unit is on the rear panel, next to the IEC mains connector.
On the front panel there is an LED ON indicator, which is lit when the unit is
functioning.
Do not allow the supply cable to become entwined or run parallel to the shielded
cables carrying the audio signal, as this could cause buzzing.