5.8. ETHERNET and RS-232 ports for programming and control

The RJ45 ETHERNET connector on the rear panel allows the connection of the unit
to an Ethernet network, either directly to a computer or to another device with an
Ethernet interface, point to point. This connection enables, within a local network,
the following:
 The Programming and overall management of the eMIMO1616 unit via the
embedded web application and a standard web browser running on a
computer, a tablet, etc.
 The connection of client devices for the end user in installation zones via
the eMIMO pilot application, which is compatible with Android and iOS, or
via standard web browsers running on computers, tablets, etc.
 The connection of third-party equipment for integration within control
systems (Crestron®, Extron®, AMX®, Vity®, Medialon®, etc., brands
registered by their manufacturers), using the TP-NET protocol embedded in
the eMIMO1616. See the TP-NET protocol manual for further information.
The DB9 RS-232 connector on the rear panel allows the connection of the unit
point to point to a computer or other control device. This connection exclusively
uses the integration via series port with third-party equipment and control
systems (Crestron®, Extron®, AMX®, Vity®, Medialon®, etc., brands registered
by their manufacturers), using the TP-NET protocol embedded in the eMIMO1616.
See the TP-NET protocol manual for further information.
The parameters necessary for a correct series connection are the following:
 Baud rate: 115200 (fixed, no autonegotiation)
 Data bits: 8
 Parity: None
 Stop bits: 1
 Flow control: None