Service Manual
6.8 Operation characteristics
Temperature
Room temperature
Outdoor temperature
BMS500-AAS009-0CSXXA
BMS500-AAS012-0CSXXA
BMS500-AAS009-1CSXXA
BMS500-AAS012-1CSXXA
BMS500-AAS018-1CSXXA
BMS500-AAS024-1CSXXA
Table 8
Equation to convert Celsius to Fahrenheit
( °F) = 1.8 x ( °C) + 32
CAUTION:
If the air conditioner is used beyond the above conditions,
certain safety protection features may come into operation
and cause the unit to operate abnormally.
The room relative humidity should be less than 80%. If the air
conditioner operates beyond this figure, the surface of the air
conditioner may attract condensation. Please set the vertical
air flow louver to its maximum angle (vertically to the floor),
and set HIGH fan mode.
The optimum performance will be achieved during this
operating temperature zone.
Bosch Thermotechnology Corp. | 02.2018
Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump | 15
Cooling operation
62℉ - 90℉
(17℃ - 32℃)
-13°F - 122°F (-25°C - 50°C)
Heating operation
32℉ - 86℉
(0℃ - 30℃)
-13°F - 122°F (-25°C - 50°C)
Drying operation
50℉ - 90℉
(10℃ - 32℃)
32°F-122°F (0°C-50°C)
Data subject to change