ELECTRICAL CONNECTIONS

1

ELECTRICAL CONNECTION REQUIREMENTS

The third step of the installation is to follow the electrical connection requirements below.
Ensure that dedicated circuit protection is prepared as recommended and that the oven is grounded properly.
IMPORTANT NOTE
Be sure the wall oven is installed and grounded properly by a qualified installer or service technician.
• This wall oven must be supplied with the proper voltage and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or fuse. To know the circuit breaker or fuse required by this
model, see the rating plate to find the wattage consumption and refer to the table below to get the circuit breaker
or fuse amperage.
Appliance Rating
Watts 220 V
less than 4400 W
4400 W - 6600 W
6600 W - 8800 W
8800 and +
• A single wall oven can consume up to 3,600 W at 220 VAC.
A 20 Amp circuit breaker with wire gauge at least #12 AWG must be used.
IMPORTANT NOTE
• Do Not ground to a gas pipe.
• Do Not have a fuse in the neutral or grounding circuit.
• A U.L.-listed conduit connector must be provided at the junction box.
WARNING
• Improper connection of aluminum
house wiring to copper leads can
result in an electrical hazard or fire.
Use only connectors designed for
joining copper to aluminum and
follow the manufacturer's
recommended procedure closely.
IMPORTANT NOTE
• The electrical outlet or fixed wiring switch MUST be accessible after installation to disconnect the oven.
Protection Circuit recommended
- 7 -
20 A
30 A
40 A
50 A