1. Mounting preparations
1
2
Caution: have all work involving the
1)
230 V mains supply carried out by a
qualified electrician! Before starting
disconnect the mains! Please be aware,
that the LUXOMAT
LC-Click-N 140/200 is
®
not suitable as an intrusion detector, since
it is not equipped with a tamper contact.
2) Socket base corner mounting
The device is not suited for safe disconnection
of the mains supply.
Important: The LUXOMAT
LC-Click-N
®
140/200 has to be mounted in such a way,
that the adjusting elements / rotary regulators
are always pointed downward.
Caution: Do not connect more than2 LUXOMAT
LC-Click-N in one circuit, to avoid any erroneous
switching.
7. Putting into operation / Settings
Self test cycle
After mounting and connecting the 230 VAC supply volta-
ge, the LC-Click-N 140/200 runs a self testing unit. Then
the unit is ready for operation and the settings can be
made manually or with remote control.
40
10
130
1000
2 Lux
1) If possible mount unit on a safe place
(wall or ceiling mount)
2. Wall mounting
Mount the plug-in socket with two screws and
the enclosed seal rings on a firm base.
(Pay attention to inserting of the connection
cable, see point 3)
3. Inserting of the connection cable
1
1) Cable entry points
2) Terminal markings
®
20
1.2
50
6
20
4
sec
10
min
1000
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
LC-Click-N 140 / 200
®
4. Sensor head optics
By swinging the sensor head horizontally
(ca. 90°) and vertically (ca. 85°) detection
area can be changed.
2
1.2
50
6
4
Follow-up time
sec
10
min
4sec. ... 10Min.
40
10
130
Lux value
Night operation...Dusk...Day operation
2 Lux
(Day operation: light sensor inactive, switching at
any brightness value)
3) Minimum distance to switched lighting,
frontally or laterally to device: 1 m
4) Never mount the connected lights below
the motion detector!
LC-Click-N 140 and LC-Click-N 200
®
5. Exclude sources of interference
If necessary, the lens segment(s) corresponds
to unwanted detection zones may be masked
with the enclosed covers to reduce the field
of vision.
6. Mounting types
1) Wall mounting
8. Range of Coverage
2,50 m
4
1 :
1 .
5
0 .
2 5
0 .
P t
2 4
o k
o
B
r a
t u
F u
> 1m
GB
1
3
1
2
1
Walking Towards
2
Walking across
3
Anti-creep
2,50 m
3
1
2
1
Walking Towards
2
Walking across
3
Anti-creep

Advertisement

loading

Summary of Contents for B.E.G. LUXOMAT LC-Click-N 140

  • Page 1 Self test cycle 2,50 m After mounting and connecting the 230 VAC supply volta- ge, the LC-Click-N 140/200 runs a self testing unit. Then the unit is ready for operation and the settings can be made manually or with remote control.
  • Page 2 Power supply: 230 V~ ±10 % 1. Lamp does not light up 4. Light source remains on for long periods when Detection area: LC-Click-N 140 no persons are present Cause - Action 140° Permanent influence from heat sources within Lamp is defective...