Download Print this page

Repair Instruction - Philips FC9302 Service Manual

Hide thumbs Also See for FC9302:

Advertisement

DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the exhaust filter
cover 13, filter foam 14 and HEPA filter 9.
- Remove the dustcover 2 by releasing the clicks in the
hinges 8 and 12. (see picture)
1
- After removing the 4 screws
removed.
A
A
- When the repair is finished, check whether all functions of
the appliance work properly.
- To disassemble the cord winder 18, use TORX screwdriver
no. T10, which is one of a set consisting of T20; T15; T10;
T9; T8; T7 and T6 (code number 4822 395 50145)
2
1
A
the upper housing 11 can be
A
A

REPAIR INSTRUCTION

- The spare parts have been standardized as much as possible.
- Depending on the original cord, the spare cord must be
shortened to the length of the original cord.
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn.
- Item 22, safety valve, opens to cool the motor if the air
displacement is too low or if the airfl ow is blocked.
- The motor must only be replaced including the complete
suspension assembly 33. (see picture)