7. General Error Function
When an error occurs, this function starts to keep generating error melody sounds and displays error indicators as
l
shown in the followings per corresponding error by blinking in 0.5sec interval until the error status is completely cleared out.
In this case, all the driving devices are turned off until the error is cleared out.
1. WATER SUPPLY ERROR
- Display shows ' E1' .
- Water Supply Error occurs when water level frequency does not show changes more than 100Hz or water is not supplied
up to the water level presetting for 20 min or more at the time of initial water supply.
- The error status can be cleared by turning POWER S/W OFF and resuming the POWER ON initial status.
2. WATER DRAIN ERROR
- Display shows ' E2' .
- In case the water level frequency is 24.5KHz or less in the initial phase of UNB-detecting cycle.
- Water Drain error can be cleared by turning POWER S/W OFF and resuming the POWER ON initial status.
3. OVER-FLOW ERROR
- Display shows ' E3' .
- Over-Flow error occurs when the water level is in abnormal operation. It can be cleared by turning POWER S/W OFF.
Water is drained prior to POWER S/W OFF and it is forced to be drained for 2 min if a frequency of more than 24.5
KHz is detected.
4. DOOR OPEN ERROR
- Display shows ' door' or ' Ed '
- Door Open error can be cleared by closing the door.
5. UNBALANCE ERROR
- Display shows ' E4' .
- Laundry load is unbalanced; loosen any tangled laundry.
- If only one item of clothing needs washing, such as a bathrobe or jeans, the final spin result might be unsatisfactory and an
" E4" error message will be shown in the display window.
- Unbalance error is cleared by POWER S/W OFF and by resuming the POWER ON initial status.
6. WATER HEATER ERROR
- Display shows ' E5,E6' .
- In case the water temperature rises by 7° C or more in 1 min. or by 2° C less in 10 min after heating is started.
- It can be cleared by turning POWER S/W OFF.
7. ASS' Y PRESSURE S/W ERROR
* Generated Frequency Signal of WATER LEVEL(W/L) S/W (KHz)
Level
Abnormal W/L Frequency
- If the same signal as the above table is detected for more than 5 seconds, it is a PRESSURE S/W Error.
- When the error occurs, water drain pump will operate for 3 min. and then turn off the water drain pump.
Then the display shows ' E7' indicating a pressure s/w error indicator.
8. ABNORMAL WATER TEMPERATURE ERROR
Course
Delicate
Wool
- In case the water temperature is 50°C or more in Delicate and Wool course.
- At the time of initial water supply, if the water temperature is not appropriate, water starts to be drained
and it is forced to be drained for 2 min when the abnormal frequency of 24.5KHz is detected.
- Display shows ' E8' .
- This error can be cleared by POWER S/W OFF.
9. WATER LEAKAGE ERROR (E9)
- Water Leakage error occures when water is drained naturally after washing program starts.
Low Level
High Level
30.00 KHz
15.00 KHz
Water Temp
50° C or more
50° C or more
12