 Flow Function
Through the recirculation pump.
High voltage input 100 ÷ 240 Vac, the dosing system is switched on.
High voltage input is off (the recirculation pump is switched off), the dosing system
shows FLOW flashing.
Lev pH= pH product level probe alarm.
Lev H
O
= Flocculant product level probe alarm.
2
2
OFA pH= Set Point not reached with the OFA time set*
pH Band= Shown when the value read is outside the SetPoint of +/- the band value
set.
*At 70% of the time set the system shows and activates the alarm relay, at 100% it
blocks the motor. Press the Enter key to reset the alarm.
Press the Enter key with the alarm active and its relay is deactivated only remaining
shown on the display.

12. PRE-DEFINED CONTROL PARAMETERS

To reset default values and settings:
 Disconnect the device
 Hold down the + and – keys simultaneously and connect the device
 Confirm the choice to reset the default parameters
Default parameters:
 Language = UK
 Set Point = 7,4 pH; Acid; OFF; Alr Band 3,0 pH; PROP
 H
O
= 6x10; 1cc/m3; 20m3/h
2
2
 Temperature = 25°C
 Calibration = FULL
 Flow Input= OFF
 Password = Disable