The programming menu can be accessed by simultaneously pressing the Cal and Set
keys for at least 3 seconds.
Upon release of the keys the display will show:
Language Display
Progrma Menu
Language
To prime the pH pump, press the UP button for at least 3 seconds and release it to stop
the operation. To prime the H
button for at least 3 seconds.
pH measurement display
Progrma Menu
pH Measure
pH Measure
Setpoint
pH Measure
Sp Type
pH Measure
OFA Time
pH Measure
Alr Band
pH Measure
Type
0000137188

8. PROGRAMMING

Press Enter and the + and – keys to change
the language:
EN
FR, EN, IT, ES, DE
O
pump repeat the same procedure pressing the DOWN
2
2
Use Enter to access the sub-menus:
Press Enter and the + and - keys to change
the Set Point value (0÷14 pH)
7.4 pH
Press Enter and the + and - keys to change
the Set Point type.
Acid
Press Enter and the + and - keys to set the
OFA time to OFF or from 1 to 240 min. (see
Off
Paragraph 9.5)
Press Enter and the + and - keys to set the
band alarm from 1 to 3 pH.
3.0pH
Press Enter and the + and - keys to change
the dosing type.
PROP
Rev. 1.0
Settings
Settings
 Setpoint
 Dos type
 OFA time
 Alr Band
Type
 Acid
Alkaline
 PROP (see Paragraph 9.1).
 ON/OFF (see Paragraph 9.2).
OFF (dosing disabled)