Seko Pool Basic Pro Evo User Manual page 11

Table of Contents

Advertisement

H
O
measurement display
2
2
Progrma Menu
H
O
2
2
Tube
Conc
Pump
Advanced Display
Progrma Menu
Avdvanced
Avdvanced
Temp.
Avdvanced
Flow
Avdvanced
Cal
Avdvanced
Password
0000137188
H
O
2
2
6x10
H
O
2
2
1.0 cc/m3
H
O
2
2
20 m3/h
25°C
On
Full
****
Rev. 1.0
Settings
Use Enter to access the sub-menus:
 Hose
 Conc.
Pump
Use Enter to modify the dimensions of
the hose (3x7 or 6x10mm) and the
system automatically calculates the flow
rate with the other hose without changing
any parameters (the factory-set hose is
6x10).
Enter the concentration value of the product
to be dosed with the 3x7 hose. This value
ranges from 1 to 4cc/m3. With the 6x10
hose the range is 1 to 15cc/m3.
Enter the value of the system recirculation
pump. It ranges from 2 to 100m³/h
Settings
Use Enter to access the sub-menus:
 Temp.
 Flow
 Cal.
Password
Press Enter and the + and - keys to set the
compensation temperature from 1 to 100°C.
If a temperature probe is connected, the
menu item will not be displayed as the
system will compensate automatically with
the value read by the probe itself.
Press Enter and the + and - keys to set the
flow to OFF or ON. This item enables or
disables the Flow inlet (see. Paragraph
10.0).
Press Enter and the + and – keys to set the
calibration to OFF or enable it to ON (Full)
Press Enter to set the system access and
modification password.
Use the + key to modify the figure and the –
key to scroll to the next figure and confirm
with Enter
11

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pool Basic Pro Evo and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Pool basic pro evo

Table of Contents