. The temperature displayed is the maximum oper-
ating temperature programmed in the Sentry for your kiln.
(This temperature is shown on the electrical data plate.) It
can be altered only at the factory. The controller will not
fire hotter than that temperature. Press
to return to
Electronics Temperature
(ELEC)
Check the Circuit Board Temperature
High temperatures in the switch box can damage the
controller circuit board, which is rated for 158°F/70°C max-
imum operating temperature. If necessary, exhaust hot air
from the room to lower board temperature.When firing
several kilns, position them at least three feet apart to allow
adequate air circulation.
From
or while firing, press
until
appears. Press
circuit board will appear. Press
turn to
.
CAUTION: Do not operate the kiln if is the ELEC
display is above 150°C/66°C.

Program Lock (LOCK)

Make a Program Tamper-Proof
With Program Lock activated, stored programs cannot
be altered or removed from memory. Use Program Lock
for repeat firings that you don't want to inadvertently
change.
Note: Program Lock does not save a Delay setting.
While a program is locked, you can enter a new Delay.
From
, press
appears.
Press
.
will appear.
To change the setting, press
Press
. Press

Configuration Code (CFG)

Information for Technicians
From
, press
appears. Press
. The factory configuration code will
appear. Press
. Press
configuration code can be changed only at the factory.

Software Version (SOFT)

From
, press
pears. Press
. The software version will appear.
Press
. Press
16
.
repeatedly
. The temperature of the
. Press
repeatedly until
(locked) or
(unlocked)
three times.
to return to
repeatedly until
to return to
repeatedly until
to return to
.

Element Test (TEST)

Test the Heating Elements and Relays
This test is useful when measuring the wall receptacle
voltage under load, and amperage with an ammeter. On a
. Press
multiple-zone kiln, the test helps determine if the relays
and thermocouples are wired to the correct zones. If you
test thermocouples with a cigarette lighter or other heat
source, use this option.
Single-Zone Kiln
From
Press
kiln temperature. The elements will turn on for
two minutes. Press any key to abort the test.
Multiple-Zone Kiln
From
to re-
Press
the temperature of the top zone. The elements will
turn on for two minutes. Then
with temperature for the middle zone, and
with temperature for the bottom zone. (A
two-zone kiln shows
only.)
During the two-minute test, press any key to end a
zone test. The controller will then begin to test the
next zone.
AOP Outlet
After the above test, kilns equipped with the AOP outlet
will display
AOP outlet.

Reset (RST)

Reset the Controller to Most Factory Defaults:
Perform Only When Requested by a Technician
Reset does the following:
Selects Type-S thermocouple.
.
Selects °F.
Erases any thermocouple offset.
Erases user programs stored in memory.
Changes Temperature Deviation (TEDE) back to the
factory setting.
. The
CAUTION: If your kiln uses a Type-K thermocouple,
the Sentry will underfire after a reset! Use the Thermo-
couple Option (page 14) to select Type-K again.
From
ap-
Press
After selecting one of the above, press
Press
, press
appears.
.
will appear, alternating with
press
appears.
.
will appear, alternating with
and
for two minutes to test power to the
, press
appears.
. Use the or key to select
.
to return to
.
repeatedly until
repeatedly until
will appear,
displays
repeatedly until
or
.