Present Status; The Alarm; Skip Segment; Editing A Segment During Firing - Orton Sentry 2.0 Operating Instructions Manual

Hide thumbs Also See for Sentry 2.0:
Table of Contents

Advertisement

Present Status

Press
during a firing to display the
current segment that is firing. Either of
the following messages will appear in
Present Status:
Ramp and segment number: The Sentry is in the
ramp part of a segment. See chart, page 6.
Hold and segment number: The Sentry is in the
hold part of a segment.
Present Status is useful when firing a program that con-
tains heating and cooling segments. Without Present Sta-
tus, it might be easy to lose track of which segment is firing.

The Alarm

The alarm sounds when the kiln
reaches the alarm temperature you enter.
Use the alarm to alert you to check the
fusing or slumping of glass or remove a knife blade from the
furnace at the end of heat treating.
You can enter only one
alarm temperature at a time.
However, after the alarm
beeps, you can set the alarm
for another temperature, as
many times as you want,
during the firing. Entering
an alarm temperature auto-
matically erases the previ-
ous alarm temperature.
Monitoring the Alarm
from a Distance
Place an inexpensive
baby monitor near the kiln.
From another location in your building, you will be able to
hear the digital temperature alarm. You will also hear the
clicking of the relays, which would indicate that the temper-
ature is still rising in the kiln.
Setting Alarm From Idle
From
, press .
with the last alarm temperature entered.
Enter alarm temperature. Press
appear. (Entering
Note:
, as an alarm temperature, automatically
changes to the maximum temperature rating of your
controller.
When the alarm sounds, shut it off by pressing any key
except
. (The
sounds.) If the alarm sounds as soon as firing begins, it is be-
cause the alarm was set to a temperature below the current
temperature.
Setting Alarm During Firing
The alarm beeps while the kiln is firing. Press .
Use the alarm to
remind you that
the kiln is getting
close to the
shut-off tempera-
ture. Always
check the kiln
before it shuts
off.
will appear alternating
.
will turn the alarm off.)
key does not work while an alarm
Enter the new temperature.
Press
If you touch , enter a new temperature, and forget to
press
without setting the alarm.
Note: When an alarm sounds, firing to completion
does not shut the alarm off.
Skip Segment Feature
Skip Segment works only during firing.
It jumps from the current segment to the
next one.
To skip a segment, press .
appear, then the current segment. Press
. (If you change your mind and
don't want to skip that segment, don't press
appears. Instead, press again. The firing will con-
tinue in the same segment.)
Skip Segment skips to the ramp of the next segment from
either a ramp or hold of the current segment.
Skip Segment Example
For additional examples, see Chapter 3.
grammed 1425°F for glass fusing, followed by a segment
for controlled cooling. Watching the glass through the
peephole, you notice that the glass edges have rounded
nicely. Use Skip Segment to end the firing segment and
begin the one for slow cooling.
Note: Make a note of the temperature at which the
glass fused. Program that temperature for the next fir-
ing of that type of glass.
Editing a Segment
During Firing
While the kiln is firing,
you can change the target
temperature and hold time
of the current segment.
During firing, press .
will
The display will show
the target temperature
of the current segment.
Use the number keys to
change the tempera-
ture. Then press
.
The display will then
show the hold time of the current segment. Change
the time, if needed, and press
resume firing.
. The kiln will continue firing.
, the controller will merely continue firing
will
With the Add
Time button, you
can add time to a
hold. With the
editing feature,
you can change
both target tem-
perature and
hold.
after
You have pro-
. The kiln will
11