Specifications - Fujitsu ASU18RLF Design & Technical Manual

For extra cold climate area, refrigerant r410a inverter, wall mounted type, indoor/outdoor
Hide thumbs Also See for ASU18RLF:
Table of Contents

Advertisement

1. Specifications

Type
Model name
Power supply
Available voltage range
Cooling
Capacity
Heating
Cooling
Input power
Heating
Cooling
Current
Heating
EER
Cooling
COP
Heating
SEER
Cooling
HSPF
Heating
Cooling
Power factor
Heating
Moisture removal
Cooling
Maximum operating current *1
Heating
Cooling
Airflow rate
Fan
Heating
Type × Q'ty
Motor output
Cooling
Sound pressure level *2
Heating
Dimensions (H × W × D)
Fin pitch
Heat exchanger type
Rows × Stages
Pipe type
Fin type
Material
Enclosure
Color
Net
Dimensions
(H × W × D)
Gross
Net
Weight
Gross
Size
Connection pipe
Method
Material
Drain hose
Size
Cooling
Operation range
Heating
Remote controller type
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) /67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) /59 °FWB (15 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) /43 °FWB (6.11 °CWB).
– Pipe length: 24 ft 6 in (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
kW
Rated
Btu/h
kW
Min.—Max.
Btu/h
Rated
Min.—Max.
kW
Rated
Min.—Max.
Rated
A
kW/kW
Btu/hW
kW/kW
Btu/hW
Btu/hW
Btu/hW
%
pints/h (L/h)
A
HIGH
MED
LOW
QUIET
3
CFM (m
/h)
HIGH
MED
LOW
QUIET
W
HIGH
MED
LOW
QUIET
dB (A)
HIGH
MED
LOW
QUIET
in (mm)
FPI
in
mm
in
mm
lb (kg)
Liquid
in (mm)
Gas
in (mm)
°F (°C)
%RH
°F (°C)
- 2 -
Wall mounted
Inverter heat pump
ASU18RLF
208/230 V ~ 60 Hz
187—253 V
5.28
18,000
2.05—6.74
7,000—23,000
6.30
21,600
2.05—8.50
7,000—29,000
1.35
0.50—3.01
1.75
0.48—3.23
6.2
7.8
3.90
13.3
3.62
12.3
20.0
10.4
95.0
97.6
5.9 (2.8)
13.5
14.5
541 (920)
435 (740)
365 (620)
306 (520)
541 (920)
435 (740)
365 (620)
318 (540)
Cross flow fan × 1
53
43
37
33
28
44
37
33
28
Main: 14-7/8 × 32-3/4 × 1-1/16 (378 × 832 × 26.6)
Sub: 3-5/16 × 32-3/4 × 1/2 (84 × 832 × 13.3)
Main: 21, Sub: 18
Main: 2 × 18, Sub: 1 × 4
Copper tube
Aluminum
Polystyrene
White
Approximate color of Munsell N 9.25/
12-5/8 × 39-5/16 × 9
320 × 998 × 228
12-9/16 × 42-15/16 × 16-7/8
319 × 1,090 × 429
31 (14)
40 (18)
Ø 3/8 (Ø 9.52)
Ø 5/8 (Ø 15.88)
Flare
PVC
Ø 15/32 (Ø 12) (I.D.), Ø 5/8 (Ø 16) (O.D.)
64 to 90 (18 to 32)
80 or less
88 (30) or less
Wireless (Wired [option])
ASU24RLF
6.44
22,000
2.90—8.00
9,900—27,300
7.38
25,200
2.20—10.61
7,500—36,200
1.76
0.58—3.42
1.94
0.50—3.53
7.9
8.6
3.66
12.5
3.80
13.0
19.5
10.5
97.0
98.1
6.3 (3.0)
15.0
15.5
659 (1,120)
530 (900)
435 (740)
365 (620)
677 (1,150)
530 (900)
435 (740)
365 (620)
49
42
37
33
49
42
37
33