Theory of Operation: Tone Remote Control Board
Smart Modem Protocol
(SMP) Control
S100 Pin 3 ON—Tone Remote
Control
30
The ASTRO Tone Remote Control Board also provides an RS232 port through
which the Consolette communicates with an ASTRO Console Interface
Module (ACIM) using the Smart Modem Protocol (SMP).
NOTE: For correct operation, the ACIM must be connected to a Gold
Series Console programmed with System 3.0 Conventional
or later.
Depending on the setting of S100-3, the operation of the Tone Remote Control
board can vary as follows:
In this setup, the Consolette can only be controlled remotely by a tone remote
deskset, via the wireline, as described in "General Description" on page 23
under "Tone Remote Control Board." The Consolette will report both PTT-IDs
and Call Alert IDs, when applicable, to Accessory Connector 1 (J13). See
Table 13. For a list of supported IDs, see Table 14 on page 31.
Table 13. Accessory Connector 1 (J13)
To
Accessory 1
of the TRC
Figure 9. TRC to ACIM Cable Diagram
J13
Signal
Pin Number
1
N/C
2
N/C
3
N/C
4
ACIM_TXD
5
N/C
6
ACIM_RXD
7
N/C
8
GND
1
2
3
ACIM_TXD
4
5
ACIM_RXD
6
7
GND
8
1
2
3
4
To the ACIM
5
6
7
8
MAEPF-27878-O
6881086C22-B