Disconnecting The Chassis Slide Assembly; Install The Chassis Slide Rails To The Appliance - IBM Slicestor 2448 Appliance Operation Manual

Table of Contents

Advertisement

Disconnect chassis section slide assembly
Refer to the following figure to open the chassis section slide assembly.
Figure 3. Disconnecting the chassis slide assembly

Install the chassis slide rails to the appliance

1. With the heads of the locating pins protruding through the set of keyhole openings in the chassis
section assembly, pull the slide toward the front of the chassis until the screw holes line up, as shown
in the following figure.
Figure 4. Install the chassis slide rails to the appliance
2. Attach the slide by inserting two M4 screws through the holes in the slide and securing them to the
chassis.
3. Repeat these steps for the other side of the chassis.
Attach the rack slide rails to the rack
1. Define the "U" spacing and attach the slide, as shown in the following figure.
8
IBM Cloud Object Storage System
: Slicestor 2448 Appliance Manual 3409-S01/3401-S01/3403-S01