Final Installation; Adjustment; Temperature Limitation; Temperature Limit Stop - Grohe Grohtherm 3000 Cosmopolitan Manual

Table of Contents

Advertisement

Final installation

1. Remove screws (C) and mounting template (D), see fig. [7].
2. Install holder (J) and fit sleeve (K) and (L), see fig. [8].
3. Grease the seals (M1) for the escutcheon mounting
bracket (M2) with the special grease supplied and install
escutcheon mounting bracket (M2) with srews (N), see
fig. [9].
4. Fit the escutcheon (M).
If the thermostat has been installed at too great a depth,
this can be adjusted by 27.5mm with an extension set (see
fold-out page I, ref. No. 47 200).
Open cold and hot water supplies.
Installation of the flow control knob (S) and adjustment of
the economy stop, see fold-out page II, figs. [10] to [12].
• The flow rate is limited by the economy stop (O) supplied,
see fig. [10].
To install the flow control knob (S), proceed as follows:
1. Close the ceramic headpart (P) by turning clockwise.
2. Install the economy stop (O) in the desired position.
For possible settings, see fig. [11].
3. Fit splined adapter (Q), see fig. [12].
4. Fit fastening set (R).
5. Install flow control knob (S) so that the button (S1) is at top.
If a higher rate is desired, the stop can be overridden by
depressing the button (S1).
Reversed connection (hot on right - cold on left). Replace
thermostatic compact cartridge (T), see Replacement Parts,
fold-out page I,Prod. no. 47 175 (1/2").

Adjustment

Installation of the temperature control handle (U) and
temperature adjustment, see fold-out page III, figs. [13]
and [14].
• Before the mixer is put into service if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat.
• After any maintenance operation on the thermoelement.
1. Open the shutt-off valve and check the temperature of the
water with a thermometer, see fig. [13].
2. Turn the adjusting nut (V) clockwise or anticlockwise until
the water temperature reaches 38 °C.
3. Fit fastening set (W), see fig. [14].
4. Install temperature control handle (U) so that the button (U1)
is at top.

Temperature limitation

The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be
overridden by depressing the button (U1), see fig. [14].

Temperature limit stop

If the temperature limit stop should be 43 °C, use handel ref.
No. 47 812 (see fold-out page I).
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be unscrewed and removed.
Maintenance
Inspect and clean all parts, replace if necessary and grease
with special valve grease.
Shut off cold and hot water supplies.
I. Thermostatic compact cartridge (T), see fold-out page III,
fig. [15] to [17].
• Loosen screw ring (X) using a 34mm tool.
• If necessary, lever out thermostatic compact cartridge (T) via
recess (T1).
• Remove screw ring (X).
Assemble in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (T), see detail (T2).
Readjustment is necessary after every maintenance operation
on the thermostatic compact cartridge (see Adjusting).
II. Non-return valve (F) or (F1), see fold-out page III
figs. [15], [16], [18] and [19].
Assemble in reverse order.
III. Ceramic headpart (P), see fold-out page III figs. [15], [16]
and [18].
Assemble in reverse order.
Observe the correct mounting positions!
Replacement parts, see fold-out page I ( * = special
accessories).
Care
For directions on the care of this fitting refer to the
accompanying Care Instructions.
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

34 278

Table of Contents