Programming System Features
The System Features Learn Routine dictates how the unit operates. It is possible to
access and change most of the feature settings using the Control button.
1.
Open a door.
2.
Turn the ignition on, then off.
3.
Select a Menu. Press and hold the Control button. The number of siren chirps
indicates the menu number. 1 chirp indicates menu 1, 2 chirps - menu 2 and
3 chirps for menu 3.
4.
When the desired menu chirps are heard, release the Control button.
5.
Select a Feature. Press and release the Control button the number of times
corresponding to the feature you wish to change. Then press and hold one
more time to select the features.
6.
Program the Feature. While holding the Control button, you can program the
feature using the remote control.
For features with only two options;
= option 1 while
= option 2.
For features with more than two options;
selects the options in ascending order,
AUX
AUX
while
selects them in descending order.
AUX
AUX
Note: Pressing
button resets the feature to the factory default.
AUX
Once a feature is programmed:
Other features can be programmed within the same menu
Another menu can be selected
The learn routine can be exited if programming is complete
To access another feature in the same menu:
1.
Press and release the Control button the number of times necessary to advance
from the feature you just programmed to the next one you want to program.
2.
Then press the Control button once more and hold it.
To select another menu:
1.
Press and hold the Control button.
2.
After 3 seconds, the unit advances to the next menu and the siren chirps, indi-
cating which menu has been accessed.
The learn routine exits if any of the following occurs:
The open door is closed
The ignition is turned On
There is no activity for 30 seconds
The Control button is pressed too many times
Bitwriter - Only Options
If programming with the Bitwriter®, the learn routine can be locked or un-
locked. If the learn routine has previously been locked, it must be unlocked
with Bitwriter® - this cannot be done manually with the Control button.
The Bitwriter®
gives you access to a wider range of system options. These
features and the adjustments that may be programmed are described in the table
below. Default settings are in bold type.
Menu
Feature
Default
Opt. 2
Opt. 3
Opt.4
Opt. 5+
Item
1
Zone 4 Sensor Type*
None
Shock/
Field
Tilt Sen-
Glass Break (5)/
Omni
Distur-
sor
Ultrasonic (6)
bance
2
Siren Duration
30 sec.
Options: 1 to 180 sec.
3
Aux/Trunk Icon Type*
Trunk
Window
Sunroof
Audio
Lights/Left dr/Right
dr/Rear Hatch
4
Aux 1 Timed Output
30 sec.
Options: 1 to 90 sec.
5
Aux 1 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/
Right dr/Rear Hatch/
Timed/Latched
6
Aux 2 Timed Output
30 sec.
Options: 1 to 90 sec.
7
Aux 2 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/
Right dr/Rear Hatch/
Timed/Latched
© 2012 Directed. All rights Reserved.
8
Aux 3 Timed Output
30 sec.
Options: 1 to 90 sec.
9
Aux 3 Icon Type*
Pulsed
Trunk
Window
Sunroof
Audio/Lights/Left dr/
Right dr/Rear Hatch/
Timed/Latched
10
Aux 4 Timed Output
30 sec.
Options: 1 to 90 sec.
11
Diesel Start Delay
15 sec.
Options: 1 to 90 sec.
Timer
12
Timer Mode Runtime
12 min.
Options: 1 to 16 min.
13
Timer Mode Starts
6 starts
Options: 1/2/3/4 to 24 (Starts) in increments of 2
14
Timer mode intervals
Options: 1/2/3/4 to 24 in 2 hour increments
3 hr.
15
Smart start low temp
Options: OFF, -20° to 70° in 10° increments
0° (F)
16
Smart start high temp
Options: OFF, 40° to 130° in 10° increments
100° (F)
17
Smart start low bat-
10.5V
Options: OFF, 9V to 12.5V in 0.5V increments
tery (volts)
18
Sensor 1 Level
7
Options: 0 to 15 in increments of 1
19
6
Options: 0 to 20 in increments of 1
Starter Release
(normal)
Fine Tune
20
Feature Programming
Unlocked
Locked
21
Transmitter Program-
Unlocked
Locked
ming
22
Remote Start Runtime
12 min.
Options: 1 to 60 min.
23
Virtual Tach Fine tune
Not Ini-
Options: Not initialized, 0 to 1000 in 50 millisecond
tialized
increments
* Only available on remote controls with display screens.
Feature Menus
Default settings are in bold type. New features are bold with grey background.
Menu 1 - Security
Menu
Feature
Opt. 1
Opt. 2
Opt. 3
Opt.4
Item
1
System Arming Mode
Active
Passive Arm
Passive
Auto re-arm
w/o lock
Arm w/
w/o lock
lock
2
Panic Mode
On
Ign Off
Off
only
3
Confirmation Chirps
On w/Warn
On w/
Off w/
Off w/
Warn
Warn
warn
chirps On
chirps Off
chirps On
chirps Off
4
Siren Duration
30 sec.
60 sec.
5
Ign-controlled Locks
No Ign-
Lock &
Lock Only
Unlock
Unlock
Only
locking
6
Door Lock Pulses
Single
Double
Double
Double
Unlock
Lock Only
Lock &
Only
Unlock
7
Door Lock Output
0.8 sec.
3.5 sec.
0.4 sec.
Duration
8
2nd Unlock
2nd unlock
2nd unlock
on Ign-
on Ign-
control after
control with
first unlock
first unlock
9
Comfort Closure
No Comfort
Comfort
Comfort
Closure 1
Closure 2
Closure
10
Horn Function
Full Alarm
Siren Func-
Siren Func-
Siren
Only
tion 20 ms
tion 30 ms
Function
40 ms
11
Hood Switch type
Normally
Normally
Open
closed
12
Sensor Full trigger
Single
Double
13
Door Switch Type
Normally
Normally
open
closed
14
Trunk Switch Type
Normally
Normally
open
closed
15
Remote Button unlock
On
Off
(Ign off)
Menu 2 - Convenience
Menu
Feature
Opt. 1
Opt. 2
Opt. 3
Item
1
One-time Bypass
One time
One time
bypass
bypass On
Off
2
Nuisance Prevention
On
Off
3
Override Pulse count
1
2
3
4
Door Trigger Error
On
Off
Chirp
5
Ign-controlled Dome
On
Off
light
6
OEM Alarm Disarm
On
Off
w/Aux-Trunk
7
OEM Alarm Disarm
With
Before
Remote
Output
Unlock
Unlock
Start Only
8
OEM Alarm Disarm
1
2
Pulses
9
Aux 1 Output type
Validity
Latch
Latch/
reset/ign
10
Aux 1 Linking
No Linking
Link to Arm
Link to
Disarm
11
Aux 2 Output Type
Validity
Latch
Latch
reset/ign
12
Aux 2 Linking
No Linking
Link to Arm
Link to
Disarm
13
Aux 3 Output Type
Validity
Latch
Latch
reset/ign
14
Aux 3 Linking
No Linking
Link to Arm
Link to
Disarm
Opt. 5+
15
Aux 4 Output Type
Validity
Latch
Latch
reset/ign
Auto
re-arm w/
16
Aux 4 Linking
No linking
Link to Arm
Link to
lock
Disarm
17
Aux/Trunk Output type
Validity
Off
2nd unlock
Menu 3 - Remote start
Menu
Feature
Opt. 1
Opt. 2
Opt. 3
Item
1
Transmission Mode
Manual
Automatic
2
Engine Checking Mode
Virtual
Voltage
Off
Tach
3
Cranking Time
0.6 sec.
0.8 sec.
1.0 sec.
4
Remote Start Runtime
12 min.
24 min.
60 min.
5
Activation Pulse Count
1
2
6
Turbo Mode
No Turbo
On-1 min.
On-3 min.
Mode
Siren Func-
7
Timer Mode Runtime
12 min.
3 min.
6 min.
tion 50 ms
8
Flex Relay Function
Ignition 2
Acces-
Starter 2
sory 2
9
Diesel Start Delay
Wait-to
Timed 15
Timed 30
Start input
sec.
sec.
10
Accessory during Diesel
On
Off
Start Delay
11
Status 2 Output
Status
Latch Rear
Pulse Rear
Defogger
Defogger
12
Parking Light Output
Constant
Pulsed
Off
13
Anti-grind Output
On
Off
14
Tach Mode Starter
Normal
Increase
Release
Opt.4
Opt. 5+
15
Vehicle Temp *
Off
On
Auto Report
16
Remote Start Safelock
Off
On
* Not applicable to 1 way remote control.
Remote Pairing
4
5
Prepare the vehicle system to be Paired with a new remote
1.
Open a door.
2.
Turn the key to the ON position.
3.
Within 5 seconds press and release the Control button on the system's Control
Center one time.
4.
Within 5 seconds, press and hold the Control button on the Control Center.
The status LED will flash one time and the siren will chirp once to confirm the
system is ready for remote pairing.
5.
Release the Control button and proceed below.
30 sec.
Off (5)/2nd
Note: If no remote pairing results, the system will exit after 60 seconds.
Timed
unlock (6)
Link to
Link to
Prepare the new remote to be Paired with the system
Arm/
Remote Start
disarm
only
Make sure the LC3 remote is set for the desired Car 1 (Default) or Car 2 opera-
tion.
30 sec.
Off (5)/2nd
Timed
unlock (6)
AUX
1.
Press and hold the
button for 8 seconds until the main menu appears.
Link to
Link to
2.
Press and release the
button until Remote Pair text is displayed.
Arm/
Remote Start
AUX
AUX
Disarm
only
3.
Press and release the
button until Pair text is displayed.
4.
Press and hold the
button until tones are played on the LC3 remote.
30 sec.
Off (5)/2nd
Timed
unlock (6)
5.
Successful or Failed Pair: The LC3 remote control indicates a successful or
AUX
failed pairing on the display.
Link to
Smart Key
Arm/
Control (Link
Disarm
to Remote
Note:
Please see installation guide for pairing with the 1-way companion remote.
Start Off)
30 sec.
Off (5)/2nd
Basic Remote Functions
A U X
Timed
Unlock (6)
Link to
Link to
DIRECT
Level
Arm/
Remote Start
X 1
ACCESS
Disarm
Only
Button
ARM
SILENT ARM
SENSOR BYPASS
DISARM
SILENT DISARM
Opt.4
Opt. 5+
REMOTE START
RUNTIME RESET
A U X
TRUNK RELEASE
AUX 1
Tachom-
A U X
eter
A U X
A U X
A U X
FUNCTION SHIFT
CABIN TEMPERA-
RUNTIME CHECK
1.2 sec.
1.4 (5)/ 1.6
TURE REQUEST
(6)/ 1.8 (7)
(2-WAY ONLY)
2.0 (8)/
4.0 (9)
Note: See Owner's guide for more details
Table of Zones
On-5 min.
On- 10 min.
A zone is represented by the number of status LED flashes used by the
system to identify a particular type of input.
9 min.
Zone
Description
Timed 45
1
Trunk Pin
sec.
2
Instant trigger: a heavier impact
detected by the shock sensor
3
Door switch trigger
4
Instant trigger: For optional sensors
5
Ignition trigger
6
Hood Pin
Decrease
A U X
A U X
A U X
X 2
X 3
X 4
ARMED (SILENT
ARMED (SILENT
SENSOR)
TRIGGER)
VALET MODE
CAR FINDER
TIMER MODE
SMART START
REAR DEFOGGER
AUX 2
AUX 3
AUX 4
LAST TRIGGER
(2-WAY ONLY)
REQUEST
(2-WAY ONLY)
Input Description
24 pin Harness Blue wire
Shock sensor.
24 pin Harness Green or Violet wire
Optional MUX port
10 pin Harness Pink wire
24 pin Harness Grey wire
QRN5704 2012-08