Invacare TDXSPBASE Service Manual page 25

Tdx sp series wheelchair base
Table of Contents

Advertisement

6
E06
Right Park Brake Fault
7
E07
Remote Fault
8
E08
Controller Fault
9
E09
Communications Fault
10
E10
General Fault
11
E11
Incompatible/incor-
rect Remote
Part No 1143209
SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING
00
Right Park Brake Drive-Time Test
Failed
01
Right Park Brake Output Enabled
When Wheelchair Idle
02
Right Park Brake Output Did not
Enable When Entering Drive Mode
03
Right Park Brake fault during
power-up testing
04
Right park brake feedback low dur-
ing drive (park brake short)
00
Local SR Fault (CPU, EEPROM,
etc.)
01
Joystick fault at the remote
02
Speed pot fault at the remote
00
Controller fault
01
RAM fault
02
ROM fault
03
CPU fault
04
EEPROM fault
05
Watchdog fault
06
Stack fault
07
Software fault
08
Power-up testing fault
09
Relay fault or precharge fault
10
Bridge fault or disable all fault
11
Electronics fault: Thermistor
12
Calibration setting fault
00
Remote connection lost
01
Low communication mode
00
General fault
00
Incompatible/incorrect Remote
25
Check the right park brake connections and
cable.
Check the communications bus, connections and
wiring. Replace the remote.
Check connections and wiring. Replace power
module.
Check connections and wiring. Replace Bus
cable.
Check all connections and wiring. Contact
Invacare Technical Service.
Wrong type of remote connected. Ensure the
branding of the joystick matches that of
controller unit.
TDX® SP