"i20" Code - family: Draining
Problem
"i20"-Code: Fails to drain
Acoustic signal and visual error, depending on
the appliance customization; the program can be
restarted
The level switch restore point is not reached within
the time limit set
The time limit set starts when the drain pump is
activated
The time limit set is reset when the drain pump
stops normally
Time limit set: Normal 90 sec; Test cycle = 60 sec.
"i30" Codes - family: Aqua
Control
"i30" code: water detected from aqua
control sensor
Acoustic signal and visual error, depending on
the appliance customization; the program is
restarted automatically in this error condition
If this error condition occurs, the drain pump is
activated
Time limit set: 10 sec.
"i40" Codes - family: Analogue
pressure sensor problem
"i41" – code: No pressure sensor signal
The error is set if the sensor signal is lost for more
than 1s
Abort program and display error.
"i42" – code: Calibration invalid,
pressure signal too noisy
The warning is set if the sensor signal is not stable
enough for calibration or if the signal is out of
range for an empty sump
The signal noise level for calibration is defined in
MCF.
"i43" – code: Pressure sensor signal
too high
The error is set if the sensor signal is out of range,
signal high for more than 1 s
The signal range is defined in MCF
Abort program and display error.
"i44" – code: Pressure sensor signal
too low
The error is set if the sensor signal is out of range,
signal low for more than 1 s
The signal range is defined in MCF
Abort program and display error.
"i45" – code: Calibration invalid,
pressure signal too low
The warning is set if the sensor signal is out of
range for an empty dw, signal low
The signal range for calibration is defined in MCF.
"i46" – code: Calibration invalid,
pressure signal too high
The warning is set if the sensor signal is out of
range for an empty dw, signal high
The signal range for calibration is defined in MCF.
"i50" Code - family: Washing
Motor Problem
"i51" – code: Asynchronous motor
problem
Acoustic signal and visual error, depending on
the appliance customisation; the programme is
suspended
The washing pump runs without being activated
by the software the cause is short-circuit
The heating element is not activated
If the error occurs, the fill Solenoid Valve is
activated up to the level pressure switch tripping