Technical Information
Driving a Bidirectional
Proportional Valve
(continued)
8
Output Configurations for PLUS+1® Controllers
Option 3 – push/pull configuration for dual coil
You may also use two outputs to drive a bidirectional dual coil valve such as a dual coil EDC when
wired as shown below. This configuration will allow you to check the resistance of the coils for more
accurate diagnostics. Setting PinConfig = 4 on both outputs will give closed loop current control.
Refererence
FMEA
Considerations, pages 10 and 11.
+Batt
Ground
+Batt
Ground
520L0922 • Rev EA • Sep 2013