TABLE OF CONTENTS INTRODUCTION Congratulations..........3 Product Description ..........3 SAFETY CONSIDERATIONS..........4 TECHNICAL DATA Features and Benefits ........5 Specifications ............6 CONTROLS & FUNCTION S ..........7 . MAKING A MEASUREMENT ........9 SAVING DATA ............10 LOADING SAVED DATA ..........10 MIN / MAX ............10 PRINTING DATA ............10 CHANGING DATE &...
B. SAFETY CONSIDERATIONS WARNING: Please follow manufacturers test procedures whenever possible. Do not attempt to measure unknown pressures. Damage to the instru- ment may result. GENERAL GUIDELINES ALWAYS • Ensure connections are secure prior to applying pres- sure. • Inspect hoses and fittings for cracks or bends prior to a pressure test.
C. TECHNICAL DATA 1. Features and Benefits Display 5 digit dual line with backlight Units of Seven units of measure (bar, kPa, Measure PSI, mmHg, inHg, mmH2O, inH2O). Logging Record test data with time stamp and display with optional software. Data Store Save up to 16 readings.
2. SPECIFICATIONS Measurement Range: ±101.5 psi (±7bar) Display: 5 Digit Dual line LCD with backlight Input Type: Differential Resolution (max): 0.01 psi (0.001 bar) (0.1 inH2O) Accuracy: 0.2% Full scale Repeatability: 0.1% Full scale Mean Temperature Coefficient: 0.1% of reading per ºC Functions: One Touch Zero, Data Hold, Back-light, Unit Selection, Data Logging, Auto power Off, Min / Max Record, Resolution Selection...
D. CONTROLS & FUNCTIONS IR Ports for PC communica- Input Connectors (1/4” NPT) tion using optional A665 docking station Display IR Port for printing using optional A740 print- Keypad 561.8187 information@itm www. .com...
Page 7
Press to change the unit of measure. Press the SHIFT key first, then this key to zero the 665 prior to making a measurement. Press to activate shift mode (red key functions). Press to cycle through bottom display modes (percent of fullscale, current time, number of logged readings.
1. Turn the 665 by pressing the key. 2. Zero the 665 by pressing 3. Connect the device under test to the “+” port of the 665. If a differential measurement is being made, connect the other pressure source to the “-” port.
Press to print readings to the optional A740 printer. The 665 will display a 10 second countdown giving you time to align the back holes approximately 4” away from the printer win- dow. “Out” will display and a 9 second countdown will proceed while printing takes place.
J. Changing the Date & Time 1. Activate “EDIT” mode by pressing and “date” is displayed. 2. Press 3. Press to cycle through month, day, and year. 4. Press to change the month, day or year. 5. Once the date has been changed press and “date”...
This mode sets up the interval or time between each logged data point. The interval can be set from 1 second to 24 hours. The 665 can log a total of 5000 data points. NOTE: The option- al A665 docking station and software is required to view logged information.
Page 12
This mode sets up start time for automaitc logging. Logging can also be activated manually (See page 12). 1. The logging interval should already be set and the 665 should be displaying “L-Int”. If not, follow steps 1 through 7 on page 12 before proceeding.
Page 13
(See page 12). 1. The logging interval and start time should already be set and the 665 should be displaying “L-St”. If not, follow steps 1 through 7 on page 12 and steps 1 through 6 on page 13 before proceeding.
Page 14
K. Logging Data (continued) Deactivating Automatic Logging This mode turns off automatic logging. 1. Activate “EDIT” mode by pressing six times until “L-res” is displayed. 2. Press 3. Press and “L-rES” and “YES” is displayed. 4. Press to cycle between NO (Cancel) and YES (Activate).
1. Remove the protective rubber boot beginning at the bot- tom, 2. Using a screwdriver loosen the two screws located at the bottom of the 665. 3. Pull on the screws to remove the bottom cover/battery holder. 4. Remove the batteries and observing polarity replace them with fresh batteries.
665 still displays “OL” the sensor is no longer working and the 665 needs service. To obtain service for your 665 please return it to: TPI / Attn: Service 9615 SW Allen Blvd Suite 104 Beaverton, OR 97005 561.8187...
O. Accessories Standard Accessories Part Number 1.5 Volt Alkaline Battery (x2) A002 Protective Boot w/ magnets A614 Optional Accessories Part Number USB cradle and software A665 561.8187 information@itm www. .com...
Need help?
Do you have a question about the 665 and is the answer not in the manual?
Questions and answers