D. Laser Inspection (VRDC/VWDC1, 2 FPD & Level check)
1. Remove disc on the Tray.
2. Select ALPC/OPC on the menu bar and select Laser Inspection menu, then Laser Power Test window
will appear.
3. Click Trigger button, then the result will be displayed with OK or NG separately.
4. Close Laser Power Test window.
[Laser Power Test Frame]
66
[Laser Inspection]
[Laser Power Test Result]