3. Other Alarm Visual and Audible Indicators
Operational Mode
normal (standby)
test (button press when
no alarm condition is
present)
Smoke Alarm Memory
(unit has experienced
a smoke alarm event
within the last hour)
Smoke Alarm Hush®
Mode, (SMArt Hush®
cOntrOl)
Smoke Alarm Hush®
Mode canceled
Initiating Alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on continuously
during light conditions, or blink every 60 sec
during dark conditions.
DC power: Green LED blink approx every 60 sec.
•
4 patterns of Red/Amber/Green.
•
Test: Red LED blinks in time with
alarm pattern.
•
Green LED fade on/off at test
complete
Red and Amber LED alternate on 1
sec, every 10 sec.
Red LED blinks every 2 sec.
None
Green LED blinks once per sec indicating
that this is the unit initiating the alarm in an
interconnected, multiple alarm, system.
Audible Indications
•
Button press sound
•
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
•
3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete," Power
on/reset sound.
•
Voice "Test Canceled" if button
pushed before test sequence begins.
After button push: "Smoke previously
detected" only on the initiating
alarm unit.
After button push: "Hush® Mode Acti-
vated." Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush®: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
Voice message "Hush® Mode
Canceled."
Unit in smoke alarm mode.
Action/Note:
Perform Test/Hush® button
press once a week to verify
proper alarm operation
* Push/release button before
the countdown ends to
cancel test.
Push test button to clear
Alarm Memory. NOTE: stan-
dard test sequence will follow.
(Push/release button again to
cancel test).
This feature is to be used
only when a known alarm
condition, such as smoke from
cooking, activates the alarm.
When smoke levels drop
below the alarm threshold,
the voice message "Hush®
Mode Canceled" will occur .
During alarm, the initiating
alarm red blink will be inter-
rupted by a green blink.
Need help?
Do you have a question about the P4010ACS and is the answer not in the manual?
Questions and answers