Me GSV-4 Operating Instructions Manual

4 channel measuring amplifier
Hide thumbs Also See for GSV-4:

Advertisement

4 channel measuring amplifier GSV-4
Updated: 02.02.2018
ME-Meßsysteme GmbH
Neuendorfstr. 18a
16761 Hennigsdorf
GSV-4BT
GSV-4USB

Operating instructions

Tel.: +49 3302 89824 60
Fax: +49 3302 89824 69
Mail: info@me-systeme.de
Web: www.me-systeme.de
1

Advertisement

Table of Contents
loading

Summary of Contents for Me GSV-4

  • Page 1: Operating Instructions

    4 channel measuring amplifier GSV-4 GSV-4BT GSV-4USB Operating instructions Updated: 02.02.2018 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 3: Table Of Contents

    Data frequency and filter........................46 Analogue filter..........................46 Digital filter............................46 Annex..............................48 Connection figures for GSV-4BT SD and GSV-4BT LD.............48 Changelog............................52 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 4: Straingage Measuring Amplifier Gsv-4Usb

    0 ... 5V can be connected. The front-end M12 socket is configured by default for strain gauge full-bridge connections and for voltage inputs 0 ... 5V and 0 ... 10V. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 5: Dimensions

    Dimensions Figure 1: Dimensions GSV-4USB SUB-D37 Figure 2: Dimensions GSV-4USB M12 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 6: Technical Data

    Protection type / Weight Protection type IP40 Weight GSV-4USB SUB-D37 Table 1: Technical data GSV-4USB ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 7: Connection Assignment

    +U S positive bridge supply brown +U D positive differential input blue -U D negative differential input black AUXin input without cable grey ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 8 Connection of full bridge with SUB-D37 version The following graphics show the connection of a full bridge to channel 1 through to channel ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69...
  • Page 9 Connection of half bridge with SUB-D37 version The following graphics show the connection of a half bridge to channel 1 through to channel The bridge extension should be adapted depending on the application. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 10 Connection of quarter bridge with SUB-D37 version The following graphics show the connection of a quarter bridge to channel 1 through to channel 4. The bridge extension should be adapted depending on the application. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 11 •HB4 when using channel 4 with a half bridge. Solder bridges: Figure 3: Solder bridges for configuring bridge extensions see page 11 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69...
  • Page 12 The bridge extension can be adapted individually for each channel; open the device and extend the desired solder bridge according to the following figure. Figure 3: Solder bridges for configuring bridge extensions ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 13 The bridge extension can be adapted individually for each channel; open the device and extend the desired solder bridge according to the following figure. Figure 4: Solder bridges for configuring bridge extensions ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 14 2.The two hexagonal bolts on the 37-pin D-Sub port must be loosened using a socket spanner (5 mm). 3.The printed circuit board is pulled out on the side of the 25-pin D-Sub port. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 15 CH 2 CH 3 CH 4 positive supply +Us positive supply +Us negative supply -Us negative supply -Us “Aux” input input ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 16 CH 1 CH 2 CH 3 CH 4 1 (+supply) pos. supply +Us 3 (GND) neg. upply -Us 2 (wiper) input ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 17 IO 5 IO 6 IO 7 IO 8 Channel 1 Channel 2 Channel 3 Channel 4 0...5V Input AUX Input ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 18: Strain Gage Measuring Amplifier Gsv-4Bt

    A battery can be charged at 5V supply voltage via an integrated charge regulator. Threshold values or digital outputs can be programmed with the 8 digital outputs Standard PIN: 0000 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 19: Dimensions

    Dimensions GSV-4BT SD GSV-4BT LD ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 20: Technical Data

    L x W x H 60 x 33 x 10 mm x mm x mm Protection type IP64 Table 3: Technical data GSV-4BT ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69...
  • Page 21: Wiring Diagram

    Wiring diagram Straingage full bridge ch 1 ch 2 ch 3 ch 4 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 22 A solder bridge should be set depending on the Straingage resistance (120/350/1000 Ohm), e.g. 120 Ohm at channel 1: Solder bridge 11 (vertical); 350 Ohm at channel 2: Solder bridge 21 (horizontal). ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 23 1000 A reference sensor PT1000 must be connected to channel 1, Ue “0-5 V” terminal, AUX and -Us. The thermocouple cable is connected to terminals +Ud and -Ud. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 24 0-5V Ue „0-5V“ 0-5V Voltage input 0-10 V ch 1 ch 2 ch 3 ch 4 0-5V Ue „0-5V“ 0-5V ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 25: Technical Data Gsv-4Bt M12

    L x B x H for GSV-4BT M12 120 x 80 x 55 mm x mm x mm Protection type for GSV-4BT M12 IP65 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69...
  • Page 26: Switch Configuration Gsv-4Bt M12

    Function Sensor-Aktor Cabel M8 Supply voltage 9...28 V DC brown Battery 4,2V white GND Supply voltage blue Battery GND black ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 27 AUX in input without cable grey Connection plan for GSV-4BT M12 Half bridge Quarter bridge Voltage input Potentiometric input ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 28: Measurement Resolution

    The achievable relation signal / noise depends on the ambient conditions (cable length, shield) and on the setted data rate. The graphic illustrates the resolution with 1m cable, measuring range ±2mV/V and 350 Ohm Straingage – Simulator on channel 1. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 29: Order Variants Gsv-4Bt

    Miniature Variant, external battery, „Long Distance“ to 300m in connection with Bluetooth USB-Dongle UD100 Bluetooth USB-Dongle UD100 Bluetooth reciever with USB Port (to 300m, in connection with GSV- 4BT M12 or GSV-4BT LD ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 30: Programming / Configuration

    Measuring range in % 16 Bit output value (hexadecimal) 10.5 105.00% FFFFh 10.0 100.00% F9E7h 0.00% 8000h -10.0 -100.00% 0618h ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 31: Measuring Range 0.0 To 5 V

    Conversion of digital output value to analogue input signal: Output value = Highbyte * 256 + Lowbyte; Input signal Ue = (output value - 32768) / 32768 * 1050 °C; ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 32: Measuring Range K Thermocouple Cable

    Code p1 p2 p3 p4 p5 p6 p7 p8 p9 set_zero save_konfiguration restore_konfiguration set_offset ch B HB B get_offset ch B set_frequency get_frequency get_serial_number set_serial_number set_threshold HB LB ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 33 B get_unit set_digital get_digital set_digital_on_off get_digital_port set_user_scale ch HB B get_user_scale ch HB B set_user_sring HB B get_user_sring reserviert ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 34: Description Of Commands

    Table 4: Command list for GSV-4 (ch = channel number), B = byte, HB = high byte, LB = low byte) Commands in grey are reserved for the initial setup or calibration. The commands shaded grey are only available after restarting.
  • Page 35 Data frequency in Hz( nominal) Data frequency in Hz( effective) 0,63 0,625 1,25 1,250 2,500 3,75 3,750 6,25 6,250 7,500 12,5 12,400 14,7 24,4 937,5 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 36 This scaling factor is stored in the EEProm of the measuring amplifier and can be read with get_user_scale. Parameters in HEX Memory No. Label Channel 1 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69...
  • Page 37: Protocol For Measured Values

    Requesting serial number 1F Setting channel 1 to zero: 0C 01 Protocol for responding to commands Responses are framed by a prefix 0x3B and a postfix from the sign 0x0D 0x0A (carriage ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 38 0x23 Send: 0x29 Receive 0x 3B 29 0100 01 30 33 33 01 0D 0A Result: Current-OFF , After switching on-ON ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 39: Digital Ios

    <p1> <p2>). The port is set with <p1>/ set_digital (0xB6 <p1> <p2>) Parameters in HEX <p2> Description Eingang Ausgang get_Value ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 40 Tara Kanal4 Slave Master SW1 rel. SW8 rel. SW1 1s SW8 1s SW1 rel. 1s SW8 rel. 1s SW1 inv. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 41 0x 3B B7 0100 02 30 33 33 01 00 0D 0A Send: 0x24 Result: IO1 is configured as an input and can be read with 0xB9 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 42 0x 20 01 01 00 The turn-on threshold of SW1 is set to 0x81 00. Send: 0x 20 02 FE 00 The turn-off threshold of SW1 is set to 0x7E 00. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 43: Analogue Input

    Specification: The measured value should be sent steadily with a frequency of approx. 12.5/s. Send: 0x23 Send: 0xA6 Send 0x24 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 44: Can Bus

    Code Table 12: Head frame for responding to commands via CAN bus Frame 1 ... n Table 13: Following frame for responding to commands via CAN bus ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 45: Configuring The Can-Id

    CAN-ID for synchronising the measurement data <p1>=0x05 To request measured values, the same CAN-ID is available for all measuring amplifiers (CAN-Sync-ID). All frames with this CAN-Sync-ID trigger the sending of a measured value. ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 46: Data Frequency And Filter

    1 kHz. It is set as an antialiasing filter for the A-D converter. This filter is permanently installed and cannot be changed. Digital filter The digital filter is indirectly set with the data frequency. The effective data frequency may ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de...
  • Page 47 0,625 ..0,625 2.5......0xA0 Table 10: data frequencies and filter properties 50 Hz Notch Filter 60 Hz Notch Filter ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 48: Annex

    Annex Connection figures for GSV-4BT SD and GSV-4BT LD Figure 6: Straingage-Quarter bridge Figure 7: Straingage-Half bridge ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 49 Figure 8: Straingage-Full bridge Figure 9: PT1000 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 50 Figure 10: Voltage Figure 11: Connection battery, optionally connection load 5V ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 51 ME-Meßsysteme GmbH Neuendorfstr. 18a Tel.: +49 3302 89824 60 Mail: info@me-systeme.de 16761 Hennigsdorf Fax: +49 3302 89824 69 Web: www.me-systeme.de...
  • Page 52: Changelog

    Updated: 02.02.2018 Version ba-gsv4_en-v2a Editor Holger Kabelitz Changes Changelog Seite 52 Changelog Version Datum Änderungen ba-gsv4-v2 27.04.17 First Version ba-gsv4-v2a 02.02.18 Wiring Plan for PT1000 with M12 plug...
  • Page 53 Subject to alterations. All information describes our products in general terms.  Made in Germany Copyright © 2018 ME-Meßsysteme GmbH Printed in Germany...

This manual is also suitable for:

Gsv-4usbGsv-4usb m12Gsv-4usb sub-d37Gsv-4bt

Table of Contents