Table of Contents Description..........................4 Models............................5 Technical Data........................6 Top hat rail housing GSV-1H....................7 Pin Configuration.......................7 Dimensions........................7 Adjustment of Input Sensitivity ..................8 Top Hat Rail Housing GSV-1HSW..................9 Functional Diagram.....................10 Pin Configuration......................11 Adjustment of Input Sensitivity..................11 Layout of Jumpers.......................12 Dimensions........................12 Option EP (cConnection of an External Potentiometer)..........12 Aluminum housing GSV-1A.....................14 Pin Configuration......................14 Adjustment of Input Sensitivity..................15...
Description The GSV-1 is a precise bridge amplifier with an analog output for strain gage full bridges. The special feature of the GSV-1 is the automatic zero balancing within just 90 milliseconds across 100% of the measurement range. The zero balancing is triggered by means of a control signal from the PLC or with a pushbutton.
Models Characteristic data Voltage supply 12V or 24V DC GSV-1L, for all versions output signal ±5V GSV-1H, GSV-1HSW, (basic equipment) limiting frequency 250Hz GSV-1A optionally 2.5kHz or 10kHz; GSV-1M remote controllable null balancing above GSV-1T8 2mV/V; GSV-1A8 input sensitivity 2mV/V, optionally 3.5mV/V or 1mV/V L-Version: Printed circuit board...
Technical Data Design GSV-1 Unit Accuracy class Measurement range ±2 mV/V optional ±1.0 and ±3.5 mV/V Connectable full bridges 4 x 350 (87) up to 1 x 5000 Bridge supply voltage Input impedance > 20 / 300pF MOhm Linearity deviation <...
Top hat rail housing GSV-1H The measuring amplifier GSV-1H is available with voltage outputs ±5V, ±10V and current output 4...20mA. The force sensor is connected to terminals 1 to 4. The voltage supply (11-28V) is connected to terminal 5 and 8 (ground). For zero setting, terminal 6 is connected to the mains supply or a control signal between 5 and 24 volts is applied.
Adjustment of Input Sensitivity Input sensitivity can be adjusted by relocating the jumper. Input sensitivity for position 1 is given in the type designation. With position 5 amplification can be adjusted continously by the trimmer "TR". Position Amplification Output voltage at sensitivity Output voltage at sensitivity factor option 2 mV/V...
Top Hat Rail Housing GSV-1HSW The measuring amplifier GSV-1H is equipped with a voltage output and a current output. It is provided with two threshold switches with a relay and a very fast peak value storage for signals up to 2.5kHz (optionally 10kHz) The bridge excitation of the measuring amplifier (terminal 1 and 2) is connected with the sensor input.
hysteresis is 2.5% of the measurement range. At outputs F1 and F2 voltages of 0.03 volts up to 1 volts are detected. Below the switching thresholds the relays are in the working state, the relay contacts are opened. The corresponding light-emitting diodes (LED) light below the switching thresholds.
Layout of Jumpers Dimensions 22,5 Depth: 114.5mm; for mounting on carrying rails according to EN50022; 1 2 3 4 On exceeding the threshold value or with the failure of 5 6 7 8 the supply voltage U the relay contacts close. The exceeding of the threshold value is signalled by the switching off of the LED.
Page 13
They are for the setting of the threshold values. Notes a) The voltage output 0...10V is realised with the amplification level "2". b) In the standard design the device is equipped with a Bessel-filter 2 order, 250 Hz. c) The calibration by the manufacturer is carried out either for the current output or for the voltage output.
Aluminum housing GSV-1A The measuring amplifier GSV-1A is available with voltage outputs ±5V, ±10V and with current output 4-20 mA. The force sensor is connected to terminals 1 to 4. The voltage supply (11-30 volts) is connected to terminal 7 and 5 (ground). For zero setting, terminal 8 is connected to the voltage supply or a control signal between 5 volts and 24 volts is applied.
Adjustment of Input Sensitivity The input sensitivity can be adjusted by moving the jumper. The input sensitivity for position 1 is specified in the type designation. In position 5, the amplification can be steplessly adjusted with the Trimmer “TR“. Position Amplification Output voltage at sensitivity Output voltage at sensitivity factor...
Page 16
Option 718 (plug) The measuring amplifier GSV-1A is also supplied with plugs of type type 718. The pin configuration is the same as that of module housing GSV-1M. Instruction Manual...
Module housing GSV-1M The measuring amplifier GSV-1M is available with voltage outputs ±5V and 0...10V. It is completely cast. The method of protection is IP67. There are two 4-pole round plugs, type 718, available for connecting. The force sensor is connected to Pin 1 to 4 or the round plug connector A (socket). The voltage supply, the analog output and the taring input are connected to the round plug B (pin contacts).
Need help?
Do you have a question about the GSV-1 and is the answer not in the manual?
Questions and answers