Download Print this page

Mitsubishi Electric GT2104-PMBD Manual page 3

Got 2000 graphic operation terminal, gt21 general description

Advertisement

JY997D65101C
Side
ENGLISH
A
Side
CHINESE
B
GT2104-PMBD, GT2104-PMBDS
GT2104-PMBDS2, GT2104-PMBLS
GT21 General Description
Manual Number
JY997D65101C
Date
Sep. 2016
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
Ethernet is a trademark of Xerox Corporation in the United States. The company
name and the product name to be described in this manual are the registered
trademarks or trademarks of each company.
Effective Sep. 2016
Specifications are subject to change without notice.
2015 MITSUBISHI ELECTRIC CORPORATION
Safety Precaution
(Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by "CAUTION" may also be
linked to serious results. In any case, it is important to follow the directions for
usage
DESIGN PRECAUTIONS
 Some failures of the GOT or cable may keep the outputs on or off. Some
failures of a touch panel may cause malfunction of the input objects such as a
touch switch. An external monitoring circuit should be provided to check for
output signals which may lead to a serious accident. Not doing so can cause
an accident due to false output or malfunction.
 Do not use the GOT as the warning device that may cause a serious
accident. An independent and redundant hardware or mechanical interlock is
required to configure the device that displays and outputs serious warning.
Not doing so can cause an accident due to false output or malfunction.
 When the GOT detects its backlight failure, the GOT disables the input
operation on the touch switch(s). Thus, operators cannot operate the GOT
with touches. The GOT backlight failure can be checked with a system signal
of the GOT.
 Even when the display section has dimmed due to a failure of the liquid
crystal section or the backlight on the GOT, the input operation of the touch
switches may still be enabled. This may cause an incorrect operation of the
touch switches. For example, if an operator assumes that the display section
has dimmed because of the screen save function and touches the display
section to cancel the screen save, a touch switch may be activated. h
touches. The GOT backlight failure can be checked with a system signal of
the GOT.
 The display section of the GOT is an analog-resistive type touch panel.
Simultaneous pressing of two or more areas on the display section may
activate the switch between those areas. Do not press two or more areas
simultaneously on the display section. Doing so may cause an accident due
to incorrect output or malfunction.
 When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to shut off the power of the GOT
promptly and power on the GOT again. Not doing so can cause an accident
due to false output or malfunction.
 If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative. A system where the GOT is
used should be configured to perform any significant operation to the system
by using the switches of a device other than the GOT on the assumption that
a GOT communication fault will occur. Not doing so can cause an accident
due to false output or malfunction.
1. GOT series User's Manual Specifications
1.1 General Specifications
Item
*1
0 to 55°C (When mounted horizontally), 0 to 50°C (When mounted vertically)
Operating ambient temperature
Storage ambient temperature
-20 to 60C
Operating ambient humidity
10% RH to 90% RH, non-condensing
Storage ambient humidity
10% RH to 90% RH, non-condensing
Compliant with
Vibration resistance
JIS B3502 and
IEC61131-2
Shock resistant
Compliant with JIS B3502 and IEC61131-2 147m/s
Operating atmosphere
No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight (as well as at storage)
*3
2000 m or less
Operating altitude
Installation location
Inside control panel
*4
 or less
Overvoltage category
Pollution degree
*5
2 or less
Cooling method
Self-cooling
Grounding with a ground resistance of 100 Ω or less by using a ground cable that has a cross-sectional area of 0.14 to 1.5
2
Grounding
mm
(solid wire), 0.14 to 1.0 mm
If impossible, connect the ground cable to the control panel.
*1 The operating ambient temperature indicates the temperature inside the enclosure of the control panel to which the GOT is installed.
*2 If the ambient temperature exceeds 40°C, the absolute humidity must not exceed 90%RH at 40°C.
*3 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0 m. Doing so may cause a malfunction. When an air purge is made inside
the control panel by adding pressure, there may be a clearance between the surface sheet and the screen, making you difficult to use the touch panel, or the sheet may
come off.
*4 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the
machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The withstand surge voltage for the equipment
with the rated voltage up to 300 V is 2500 V.
*5 This indicates the occurrence rate of conductive material in an environment where a device is used. Pollution degree 2 indicates an environment where only non-
conductive pollution occurs normally and a temporary conductivity caused by condensation shall be expected depending on the conditions.
*6 DC5V type is not required ground.
1.2 Performance Specifications
Item
GT2104-PMBD
Display device
TFT monochrome display
Screen size
4.5"
Resolution
384 × 128 dots
Display size
109.4(4.31) (W) × 36.5(1.44) (H) mm(inch)
Displayed number
16-dot standard font: 24 characters × 8 lines (two-byte characters)
D i s pl a y
of characters
12-dot standard font: 32 characters × 10 lines (two-byte characters)
section
*1*2
Display color
Monochrome (black and white) 32 scales
B r i g h t n e s s
32 levels
Adjustment
Backlight
5 colors LED (white, green, pink, orange, red) (Not replaceable)
*3
Approx. 50000 h (operating ambient temperature: 25°C, display intensity: 50%)
Backlight life
Type
Analog resistive film
Key size
Minimum 2 × 2 dots (per a key)
To u c h
*4
panel
*5
Simultaneous press Simultaneous press prohibited
(only 1 point can be pressed)
Life
1 million times or more (Operating force: 0.98 N or less)
User memory
Memory for storage (ROM): 6 MB
U s e r
capacity
memory
L i f e ( n u m b e r o f
capacity
100000 times
write times)
Battery GT11-50BAT lithium battery
Battery
Life
Life Approx. 5 years (operating ambient temperature: 25°C)
RS-232 (rear face)
-
RS-232 (side face)
-
1 channel Transmission speed: 115200/
B u i l t - i n
57600/38400/19200/9600/4800 bps
interface
Connector shape: terminal block 5-pin
*6
RS-422/485
Terminating resistor
: OPEN/110 Ω/
330 Ω
(Switched with the terminating resistor
setting switch)
RS-422
-
Side
A
DESIGN PRECAUTIONS
 When the security of the GOT and relevant information need to be protected
against illegal access from an external device via the Internet, take measures at
the user's discretion.
Failure to do so may cause the configured information to be read out illegally.
DESIGN PRECAUTIONS
 Do not bundle the control and communication cables with main-circuit, power or
other wiring. Run the above cables separately from such wiring and keep them a
minimum of 100 mm apart. Not doing so noise can cause a malfunction.
 Do not press the GOT display section with a pointed material as a pen or driver.
Doing so can result in a damage or failure of the display section.
 When a GOT2000 series model and a GOT1000 series model are on an Ethernet
network, do not set the IP address 192.168.0.18 for the GOTs and the controllers
on this network.
Doing so can cause IP address duplication at the GOT startup, adversely
affecting the communication of the device with the IP address 192.168.0.18.
The operation at the IP address duplication depends on the devices and the
system.
 Turn on the controllers and the network devices to be ready for communication
before they communicate with the GOT. Failure to do so can cause a
communication error on the GOT.
 When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
MOUNTING PRECAUTIONS
 Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT main unit to/from the panel. Not doing so
can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
 Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire,
malfunction or product damage or deterioration.
 When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range (0.20 N·m to 0.25 N·m) with a Phillips-head screwdriver
No.2. Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage
of the screws or the GOT.
 Remove the protective film of the GOT. When the user continues using the GOT
with the protective film, the film may not be removed.
 Operate and store the GOT in environments without direct sunlight, high
temperature, dust, humidity, and vibrations.
 Do not use the GOT in an environment with oil or chemicals. Doing so may cause
failure or malfunction due to the oil or chemical entering into the GOT.
WIRING PRECAUTIONS
 Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or
malfunctions.
WIRING PRECAUTIONS
 Please make sure to ground FG terminal of the GOT power supply section by
applying 100 Ω or less which is used exclusively for the GOT. Not doing so may
cause an electric shock or malfunction.
 Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product. Not doing so can cause a fire or failure.
 Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.22 N·m to 0.25 N·m). Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to the
damage of the screws or the GOT.
 Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
 Plug the communication cable into the GOT interface or the connector of the
connected unit, and tighten the mounting screws and the terminal screws in the
specified torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction dueto the damage of the
screws or unit.
TEST OPERATION
PRECAUTIONS
 Before performing the test operations of the user creation monitor screen (such as
turning ON or OFF bit device, changing the word device current value, changing
the settings or current values of the timer or counter, and changing the buffer
memory current value), read through the manual carefully and make yourself
familiar with the operation method. During test operation, never change the data
of the devices which are used to perform significant operation for the system.
False output or malfunction can cause an accident.
Specifications
*2
*2
Frequency
Acceleration
Half amplitude
5 to 8.4 Hz
-
Under intermittent
vibration
8.4 to 150 Hz
2
9.8m/s
5 to 8.4 Hz
-
Under continuous
vibration
2
8.4 to 150 Hz
4.9m/s
2
(15G) Three times in each X, Y, or Z direction
2
2
(stranded wire), or 0.25 to 0.5 mm
(rod terminal with an insulation sleeve).
*6
Specifications
GT2104-PMBDS
GT2104-PMBDS2
1 channel Transmission speed: 115200/
1 channel Transmission speed: 115200/
57600/38400/19200/9600/4800 bps
57600/38400/19200/9600/4800 bps
Connector shape: MINI-DIN6-pin
Connector shape: MINI-DIN6-pin
(female)
(female)
1 channel Transmission speed: 115200/
-
57600/38400/19200/9600/4800 bps
Connector shape: terminal block 9-pin
1 channel Transmission speed: 115200/
57600/38400/19200/9600/4800 bps
Connector shape: terminal block 9-pin
*6
-
Terminating resistor
: OPEN/110 Ω/
330 Ω
(Switched with the terminating resistor
setting switch)
-
-
STARTUP/MAINTENANCE
PRECAUTIONS
 When power is on, do not touch the terminals. Doing so can cause an electric
shock or malfunction.
 Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not doing so can cause the unit to fail or
malfunction. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
STARTUP/MAINTENANCE
PRECAUTIONS
 Do not disassemble or modify the unit. Doing so can cause a failure,
malfunction, injury or fire.
 Do not touch the conductive and electronic parts of the unit directly. Doing so
can cause a unit malfunction or failure.
 The cables connected to the unit must be run in ducts or clamped. Not doing so
can cause the unit or cable to be damaged due to the dangling, motion or
accidental pulling of the cables or can cause a malfunction due to a cable
connection fault.
 When unplugging the cable connected to the unit, do not hold and pull from the
cable portion. Doing so can cause the unit or cable to be damaged or can cause
a malfunction due to a cable connection fault.
 Do not drop the module or subject it to strong shock. A module damage may
result.
 Before touching the unit, always touch grounded metals, etc. to discharge static
electricity from human body, etc. Not doing so can cause the unit to fail or
malfunction.
 Replace battery with GT11-50BAT by Mitsubishi electric Co. only.
Use of another battery may present a risk of fire or explosion.
 Dispose of used battery promptly.
Keep away from children. Do not disassemble and do not dispose of in fire.
TOUCH PANEL
PRECAUTIONS
 For the analog-resistive film type touch panels, normally the adjustment is not
required. However, the difference between a touched position and the object
position may occur as the period of use elapses. When any difference between
a touched position and the object position occurs, execute the touch panel
calibration.
 When any difference between a touched position and the object position occurs,
other object may be activated. This may cause an unexpected operation due to
incorrect output or malfunction.
PRECAUTIONS WHEN THE
DATA STORAGE IS IN USE
 If the SD card mounted on drive A of the GOT is removed while the GOT is
accessed, processing for the GOT might be interrupted about for 20 seconds.
The GOT cannot be operated during this period. The functions that run in the
background including a screen updating, alarm, logging, scripts, and others are
also interrupted. Since this interruption makes an impact to the system
operation, it might cause failure. After inhibiting access to the SD card on the
GOT utility screen, check that the SD card access LED is off and remove the SD
card.
PRECAUTIONS WHEN THE
DATA STORAGE IS IN USE
 If the data storage mounted on the GOT is removed while the GOT is accessed,
the data storage and files are damaged. To remove the data storage from the
GOT, check that the access to the data storage in SD card access LED, the
system signal, and others is not performed.
 When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out. Failure to do so may cause the SD card to drop from
the GOT, resulting in a failure or break.
 Before removing the USB device from the GOT, follow the procedure for
removal on the utility screen of the GOT. After the successful completion dialog
is displayed, remove the USB device by hand carefully. Failure to do so may
cause the USB device to drop from the GOT, resulting in a failure or break.
DISPOSAL PRECAUTIONS
 When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to the
local regulations.
(Refer to the GOT2000 Series User' Manual (Hardware) for details of the
battery directive in the EU member states.)
TRANSPORTATION
PRECAUTIONS
 When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User' Manual (Hardware) for details of the
regulated models.)
Item
Ethernet
B u i l t - i n
interface
USB (Device)
SD card
Buzzer output
Sweep Count
Productive structure
3.5 mm
10 times in each X,
Y, or Z direction
-
External dimensions
1.75 mm
-
Panel cut dimensions
-
Weight (excluding a fitting)
Compatible software package
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel due to its characteristics. It is impossible to completely avoid this symptom, as
the liquid crystal display comprises of a great number of display elements. In addition, color tone difference, unevenness of brightness, or flickers may occur due to
individual differences of liquid crystal display panels. Please note that these symptoms occur due to GOT's characteristic and are not caused by product defect.
*2 Flicker may occur due to vibration, shock, or display color.
*3 Settings the screen saving backlight to OFF prevents the display screen from burn-in and enables the backlight to lengthen its life.
*4 When using a stylus pen, it will be 100,000 times. (The specifications must be satisfied the following condition.)
- Material: Polyacetal resin - Tip radius: 0.8 mm or more
*5 If you touch two or more points on the touch panel simultaneously and a switch is placed between the two points, the switch may be activated. Do not touch two or more
points on the touch panel simultaneously.
*6 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection.
*7 Note that this does not guarantee all users' operation environment. In addition, the GOT may not be usable in the environment where oil or chemicals are splashed over
for a long time or where oil mist is filled.
1.3 Power Supply Specifications
Item
Input power supply voltage
Under the maximum load
P o w e r
consumption
At backlight off
Inrush current
Permissible instantaneous power failure
time
Noise immunity
Dielectric withstand voltage
GT2104-PMBLS
Insulation resistance
Electrical wire size
Wire type
Temperature rating of a wire
Ferrules with plastic sleeve
Crimper type
Tightening torque (terminal screws)
2. Wiring of connection cable
The diagram below shows cable assignment for GOT port.
Cables for GT2104-PMBD: GT21-CR4-8P5, GT21-CR4-25P5
Cables for GT2104-PMBDS: GT10-CR4-8P, GT10-CR4-25P
Cables for GT2104-PMBDS2: GT10-C30R2-6P
Cables for GT2104-PMBLS: GT10-CR4-8P
GOT
GT21-C□□□R4-8P5
GT10-C□□□R4-8P
GOT
Untied
(terminal
wire
-
block)
color
24V
Brown
SDA
SDB
Red
RDA
Orange
-
RDB
Yellow
SG
Green
*1
Black
*1
RSA
RSB
*1
White
*1
CSA
*1
-
+
CSB
*1
-
*1 The cable for GT2104-PMBD does not have the connection to a signal name
(RSA, RSB, CSA, CSB).
User-made cable is necessary, depending on the PLC.
For the detail, refer to GOT2000 Series Connection Manual.
1 channel Transmission speed: 115200/
Cable jacket to remove
57600/38400/19200/9600/4800 bps
Connector shape: terminal block 9-pin
Tightening torque
Recommended Tool (Screwdriver)
TRANSPORTATION
PRECAUTIONS
 Make sure to transport the GOT main unit and/or relevant unit(s) in the manner
they will not be exposed to the impact exceeding the impact resistance
described in the general specifications of this manual, as they are precision
devices. Failure to do so may cause the unit to fail. Check if the unit operates
correctly after transportation.
 When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden packaging
from insects, they cause malfunction when entering our products. Please take
necessary precautions to ensure that remaining materials from fumigant do not
enter our products, or treat packaging with methods other than fumigation (heat
method). Additionally, disinfect and protect wood from insects before packing
products.
Certification of UL, cUL standards
 Using GOT
GOT is for use on a Flat Surface of a Type 1 Enclosure.
Notification of CE marking
The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (2004/108/EC) when used as
directed by the appropriate documentation.
 This product is designed for use in industrial applications
- Type: Graphic Operation Terminal
- Models: GOT series
Standard
EN61131-2 : 2007
Programmable
controllers -
Equipment,
requirements and
tests
For more details please contact your local Mitsubishi Electric sales site.
For details of CE marking, refer to the following.
GOT2000 series User's Manual
Manual
The following shows manuals relevant to this product.
Detailed Manual
GOT2000 Series User's Manual (Hardware)
GOT2000 Series User's Manual (Utility)
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the
drawing software used.
Relevant Manuals
For relevant manuals, refer to the Help or the PDF manuals stored in the DVD-ROM
for the drawing software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (http://www.MitsubishiElectric.co.jp/fa).
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
Refer to the GOT2000 Series User's Manual (Hardware) for the connection instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User's Manual (Hardware).
Bundled Items
Model name
GT2104-PMBD/
PMBDS/
PMBDS2/
PMBLS
PLC Communication Connector
Panel Mounting Bracket (with M4 × 20 screws)
Panel Mounting Packing
GT21 General Description (This manual)
Specifications
GT2104-PMBD
GT2104-PMBDS
1
c h a n n e l
D a t a
t r a n s f e r
method:10BASE-T/100BASE-TX
-
Connector shape: RJ-45 (modular jack)
1 ch
Maximum transfer rate: Full-Speed 12 Mbps Connector shape: USB Mini-B
1 channel SDHC card supported (max. 32 GB)
Single tone (tone length adjustable)
*7
Outside the enclosure: IP67F
Inside the enclosure: IP2X
145(5.7) (W) × 76(3.0) (H) ×
145(5.7) (W) × 76(3.0) (H) × 29.5(1.17) (D) mm
32.5(1.28) (D) mm
137(5.4) (W) × 66(2.6) (H) mm
0.3kg
GT Works3 Version1.131M or later
GT2104-PMBD
GT2104-PMBDS
DC24 V (+10%, -15%)
2.9 W or less
2.2 W or less
2.2 W
1.5 W
30 A or less (1ms, 25°C, at the maximum load)
Within 5ms
Noise voltage: 1000 Vp-p, Noise width: 1 μs (by noise simulator of 30 to 100 Hz noise frequency)
500 VAC for 1 minute
(between the GOT's power supply terminals and the GOT's grounding terminal)
10 MΩ or larger by insulation resistance tester
(between the GOT's power supply terminals and the GOT's grounding terminal)
No. of wire per terminal: 1 Solid wire 0.14 to 1.5 mm
Ferrules with plastic sleeve 0.25 to 0.5 mm
No. of wire per terminal: 2 Solid wire 0.14 to 0.5 mm
Use copper or copper-clad aluminum conductors.
More than 70°C
AI 0.25-6BU (AWG24), AI 0.34-6TQ (AWG22), AI 0.5-6WH (AWG20) (Phoenix Contact Inc.)
CRIMPFOXZA3 (Phoenix Contact Inc.)
0.22 to 0.25 N·m
This manual confers no industrial property rights or any rights of any other
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
PLC
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
PLC connection cable
compensation to:
(1) Damages caused by any cause found not to be the responsibility of
Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi
products.
(3) Special damages and secondary damages whether foreseeable or not,
GT21-C□□□R4-25P5
compensation for accidents, and compensation for damages to products
GT10-C□□□R4-25P
GT10-C30R2-6P
other than Mitsubishi products.
GOT
Untied
GOT
Untied
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
(terminal
wire
(terminal
wire
and other tasks.
block)
color
block)
color
24V
24V
SDA
Brown
SD
Brown
SDB
Red
RD
Red
RDA
Orange
ER
Blue
RDB
Yellow
DR
Yellow
This product has been manufactured as a general-purpose part for general
SG
Green
SG
Green
industries, and has not been designed or manufactured to be incorporated in
*1
RSA
Blue
RS
Purple
a device or system used in purposes related to human life.
RSB
*1
Purple
CS
*1
*1
CSA
Black
NC
Before using the product for special purposes such as nuclear power, electric
CSB
*1
White
*1
NC
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
7 mm (0.27")
0.22 to 0.25 N·m
SZS 0.4 × 2.5 (Phoenix Contact Inc.)
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Remark
Compliance with all relevant aspects of the standard.
EMI
(Radiated Emissions)
Compliance with all relevant aspects of the standard.
(ESD, RF electromagnetic field, EFTB, Surge, RF
EMS
c onduc ted dis turbanc es and P owe r frequ ency
magnetic field)
Manual number
Manual name
(Model code)
SH-081194ENG-A (1D7MJ5)
SH-081195ENG-A (1D7MJ6)
© 2014 MITSUBISHI ELECTRIC CORPORATION
Remark
GOT main unit
(The maintenance supplies below are packed with the product.)
Model name
Remark
1
4
1
1
GT2104-PMBDS2
GT2104-PMBLS
-
-
-
0.28kg
GT Works3 Version1.137T or later
Specifications
GT2104-PMBDS2
GT2104-PMBLS
DC5V (±5%)
1.1W or less
0.7W
-
-
-
-
2
2
AWG26 to AWG16, Stranded wire 0.14 to 1.0 mm
AWG26 to AWG18,
2
AWG24 to AWG20
2
2
AWG26 to AWG20, Stranded wire 0.14 to 0.2 mm
AWG26 to AWG24
For safe use

Advertisement

loading

This manual is also suitable for:

Gt2104-pmbdsGt2104-pmbds2Gt2104-pmbls