Bold Text: This option changes the window's bold text color. The currently selected color
displays in the option line as it is changed. Available colors are White, Yellow, Green, Teal, Cyan,
Blue, Dark Blue, Purple, Pink, Orange, Red, Maroon, Brown and Light Grey. The default color is
White. This value cannot be identical to the Normal Text or Background value.
Window Size: This option allows you to specify the window's text width size. Available values are
widths of 80 columns or 132 columns. The length for both widths is 26 lines.
The following options for the Terminal Application menu's Configuration window enable you to define the
function keys that perform a selected action. To specify a new function key, press and hold the Ctrl key,
then press the function key that you want to associate with the action. For example, if you want to change
the Configuration (Config) Key Sequences option from Ctrl-F8 to Ctrl-F7 , press and hold the Ctrl key and
then press F7 .
Config Key Sequences: This option allows you to define the key combination that makes the
Terminal Application menu's Configuration window appear. The default key sequence is Ctrl-
F8.
On-Line Key Sequence: This option allows you to define the key sequence that displays the
On-Line mode. The default key sequence is Ctrl-F10 .
Help Key Sequence: This option allows you to define the key combination that displays the
Help System window. The default key sequence is Ctrl-F11.
History Key Sequence: This option allows you to define the key combination that enables
History mode. The default key sequence is Ctrl-F9.
Clear History Key Sequence: This option allows you to define the key combination that clears
the history buffer while in History mode. The default key sequence is Ctrl-F11.
Break Key Sequence: This option allows you to configure the key combination that generates a
break condition. The default key sequence is Alt-B.
To configure a serial IQ module:
1.
Press Ctrl-F8. The Configuration window appears.
2. Select a parameter to change. You can navigate the Configuration window using the Up Arrow
and Down Arrow keys.
3. Modify the selected value using the Left Arrow and Right Arrow keys.
4. Repeat steps 2 and 3 to modify additional values.
5. Press Enter to save your changes and exit the Configuration window.
-or-
Press Escape to exit the Configuration window without saving the changes.
C.3 Creating a serial IQ module macro
Pressing the Page Down key when the Terminal Applications menu's Configuration window is displayed
provides access to the Macro Configuration window. The serial IQ module can be configured with up to 10
macros. Each macro can be up to 128 characters in length.
To create a macro:
1.
Select the serial IQ module you wish to configure and press Ctrl-F8 to activate the Terminal
Applications menu's Configuration window.
Vertiv | Avocent® AutoView™ 2108/2216/3108/3216 Switch Installer/User Guide |
53