Company
G. Drain Pump
1.
Remove base access panel as in D).
2.
Release drain hose by gently pulling away from pump.
3.
Twist pump motor anti-clockwise to release it from the sump.
4.
Ensure 'O' ring is positioned correctly to avoid leaks.
H. Pressure Switch
1.
Facing the front of machine remove right
hand side panel as in A).
2.
Using suitable pliers squeeze clip and
release pressure switch.
3.
Disconnect wiring.
I.
Overflow Unit
(base float switch)
1.
Facing the front of machine remove
right hand side panel as in A).
2.
Release clip and slid unit from base
frame.
3.
Disconnect wiring.
4.
Float and switch can now be
separated from unit.
J.
Air-break & Turbine
1.
Facing the front of machine remove l/h side
panel as in A).
2.
Unscrew the ring nut fixing the air-break to
the D/W tank.
3.
Disconnect flow meter wiring.
4.
Lift air-break up and release from water
softener.
5.
Disconnect inlet pipe.