Advertisement

4.4 DC CURRENT

Range
400
V
µ
4mA
40mA
400mA
10A
Overload Protection: F 500mA fuse for
-18-
Resolution
0.1
A
µ
1
A
µ
10
A
µ
0.1mA
1mA
A and mA ranges, F 10A fuse for A range.
µ
Accuracy
± 0.8% of rdg ± 2 digits
± 0.8% of rdg ± 2 digits
± 0.8% of rdg ± 2 digits
± 1.2% of rdg ± 2 digits
± 2.0% of rdg ± 5 digits