Magnaflux 133033 Operating Manual

Fsm-2 field strength measuring gauge

Advertisement

Quick Links

Operating Manual

FSM-2 Field Strength Measuring Gauge
Part Number 133033

Advertisement

Table of Contents
loading

Summary of Contents for Magnaflux 133033

  • Page 1: Operating Manual

    Operating Manual FSM-2 Field Strength Measuring Gauge Part Number 133033...
  • Page 2: Table Of Contents

    CONTENTS 1. APPLICATION Application The field strength meter FSM- 2, in conjunction with the tangential field probe, digitally registers and displays magnetic field strengths (H) in the range of ± 400 A/ Safety information cm, enabling you to measure direct magnetic fields as well as alternating magnetic Identifying parts fields.
  • Page 3: Identifying Parts

    2. IDENTIFYING PARTS Socket for Socket for connecting to power supply connecting the tangential Compartment for RS232 data field probe battery pack (9V) output socket LCD display with selectable backlight ON/OFF button (see below) Cover for closing the bottom of the MODE or RMS/PEAK button device (see (see below)
  • Page 4: Supply

    Power supply socket 2.1 SUPPLY The FSM-2 meter is suitable for operation with an external power supply (12 V = / The FSM-2 field strength meter is supplied with: 125 mA) in combination with a 9V battery (NiCd or NiMH). The battery is permanently fed with a small current (maintenance charge).
  • Page 5: Operation

    3. OPERATION PEAK The PEAK function displays the highest values of the positive or negative peak values for the actual magnetic field without a sign. This allows a quick assessment 3.1 SWITCHING ON of the maximum field strength without considering the polarity. A short press on the ON/OFF key will turn the device on.
  • Page 6: Tangential Field Probe

    3.4 TANGENTIAL FIELD PROBE Operational mode selection With the FSM-2 in normal operating mode (not in setup mode), press the MODE or The tangential field probe can be permanently connected to the FSM-2 via the RMS/PEAK button (depending on the model) to cycle through the following display socket on top of the unit.
  • Page 7: Calibration

    FOR MAGNAFLUX MEASURING INSTRUMENTS NOTE: if you order a reference standard once you have started using the FSM-2, you will need to send the entire unit to Magnaflux GmbH for calibration. 3.5.1 Tangential field probe FSM-2 with reference standard (optional) The display accuracy of the FSM-2 should be periodically checked using a refer- ence standard.
  • Page 8 Bahnhofstr 94-98, 73457 Essingen, Deutschland Telephone: +49 (0) 7365 81-0 Fax: +49 (0) 7365 81-449 Email: sales.de@magnaflux.com Web: eu.magnaflux.com/de Faraday Road, South Dorcan Industrial Estate, Swindon, SN3 5HE, UK Telephone: + 44 (0)1793 524566 Fax: +44 (0)1793 490459 Email: sales.eu@magnaflux.com...