Download Print this page

Unregister One Channel Or System Device; Unregister All Channels; Fr Miscellaneous Functions; Technical Data - Uponor X-163 Quick Manual

Smatrix wave system

Advertisement

UK

Unregister one channel or system device

When a channel or system device is inaccurately
CZ
registered or if a thermostat registration needs to be
redone, it is possible to remove the current registration
from the controller.
DE
To unregister a channel:
1. Enter registration mode. Channel 1 LED fl ashes red/
DK
green, or the fi rst unregistered channel fl ashes red.
2. If a system device (interface etc) is to be
EE
unregistered, enter system channel registration
mode. The power LED fl ashes according to the
pattern long blink, short pause, long blink and
ES
channel 1 LED fl ashes red/green.
3. Use buttons < or > to move the pointer (LED
fl ashes red) to the selected channel (fl ashes green if
FI
registered) to unregister.
4. Press the < and > buttons simultaneously until the
FR
LED for the selected channel starts fl ashing red
(about 5 seconds).
HR
HU
IT

Technical data

LT
General
IP
LV
Max. ambient RH (relative humidity)
Thermostat and timer
NL
CE marking
Low voltage tests
EMC (electromagnetic compatibility requirements) tests
NO
ERM (electromagnetic compatibility and radio spectrum matters) tests
Power supply
Voltage
PL
Operating temperature
Storage temperature
Radio frequency
PT
Transmitter duty cycle
Connection terminals (thermostats only)
RO
Antenna
Power supply
Radio frequency
RU
Transmitter duty cycle
Receiver class
SE
SK
1 2
Q U I C K G U I D E

Unregister all channels

When one or more channels (thermostats and system
devices) are inaccurately registered, it is possible to
remove all registrations at the same time.
To cancel all channel registrations:
1. Enter registration mode. Channel 1 LED fl ashes red/
green, or the fi rst unregistered channel fl ashes red.
2. Press the < and > buttons simultaneously until the
LEDs for all channels except one turn off (about
10 seconds). The one remaining fl ashes red.
Miscellaneous functions
See full manual for more information about
Autobalancing of actuators (eliminating the need of
manual balancing,on by default), Cooling, and Comfort/
ECO settings etc.
IP20 (IP: degree of inaccessibility to active parts of the product
and degree of water)
85% at 20 °C
EN 60730-1* and EN 60730-2-9***
EN 60730-1 and EN 301-489-3
EN 300 220-3
Two 1.5 V AAA alkaline batteries
2.2 V to 3.6 V
0 °C to +45 °C
-10 °C to +65 °C
868.3 MHz
<1%
0.5 mm² to 2.5 mm²
From controller
868.3 MHz
<1%
2
U P O N O R S M AT R I X WAV E · Q U I C K G U I D E

Hide quick links:

Advertisement