Greenwood SK200A Installation Instructions Manual

Greenwood SK200A Installation Instructions Manual

Continuous applications, centrifugal fans for kitchens & utility rooms

Advertisement

Quick Links

SK200 install AW 3.6.10
4/6/10
01:58
Environmental
Slotvent
SK200A for Continuous Applications
SK200B2, MA & T Centrifugal Fans
for Kitchens & Utility Rooms
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SK200A and is the answer not in the manual?

Questions and answers

Shahid Mehmood
April 9, 2025

Greenwood sk200ma I want to change broken pull cord

User image 67f6e0aa44fec

Summary of Contents for Greenwood SK200A

  • Page 1 SK200 install AW 3.6.10 4/6/10 01:58 Page 1 Environmental Slotvent SK200A for Continuous Applications SK200B2, MA & T Centrifugal Fans for Kitchens & Utility Rooms...
  • Page 2 When installing wall mounted fans, SK200A – Dual speed operation, continuous at low ensure that there are no buried speed, boost via remote switch, light switch or pull cord. cables or pipes in the way. It is SK200B2 –...
  • Page 3 SK200 install AW 3.6.10 4/6/10 01:58 Page 4 Wall Mounted with rear exit installation >1˚ Ø Cut out for surface mounted cabling Tighten 3 screws to secure Ø = 125mm Replace grille Fit 2 cover screws and tighten, ensure corners Slide the top of the cover mounting clip into alignment.
  • Page 4 SK200 install AW 3.6.10 4/6/10 01:58 Page 6 Wall Mounted with side exit installation Ceiling Mounting Flexible Ducting External Grille or Airbrick GG42 or RAB NOTE: Remove shutter flap if using flexible duct DO NOT DISTORT BACKPLATE WHEN FITTING See page 10 for wiring instructions Cut an opening through the ceiling for the exhaust outlet and cable if surface mounted, or for the fan if recess...
  • Page 5 SK200 install AW 3.6.10 4/6/10 01:58 Page 8 Ceiling Mounted – Surface Ceiling Mounted – Recessed 310mm 225mm Fitting for side exhaust Ø 122mm Template enclosed with fan must be used Fitting for rear exhaust NOTE: Remove shutter flap if using flexible duct SEE PAGE 10 FOR WIRING INSTRUCTIONS DO NOT DISTORT BACKPLATE WHEN FITTING NOTE: Remove shutter flap if using flexible duct...
  • Page 6: Wiring Diagrams

    The fans are double insulated and do not Fuse Specification: 230 V ~ 50Hz. require an earth connection. Consumption: NOTE: SK200A Max 36W Continuous 21W Mains cable must be fixed back to the wall High SK200B2 Max 80W. Slow 22W speed using appropriate cable cleats.
  • Page 7 3. Repairs have not been attempted other than by Greenwood’s service staff or authorised dealers; and 4. In Greenwood’s sole discretion, the Product is found to be faulty. If it were not found to be faulty, the Product would be available for collection from the relevant Greenwood’s premises within one calendar month and if it was not collected, it would be subsequently delivered...