14.2. Sensible Capacity Chart
● CS-E15DKEW CU-E15DKE
230V
Indoor wet
bulb temp.
TC
17.0°C
4.36
19.0°C
19.5°C
4.79
22.0°C
5.22
● CS-E18DKEW CU-E18DKE
Indoor wet
bulb temp.
TC
17.0°C
5.26
19.0°C
19.5°C
5.77
22.0°C
6.29
● CS-E21DKES CU-E21DKE
Indoor wet
bulb temp.
TC
17.0°C
6.25
19.0°C
19.5°C
6.86
22.0°C
7.48
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
30
35
SHC
IP
TC
SHC
3.31
1.25
4.08
3.17
4.40
3.46
1.28
4.48
3.33
3.59
1.30
4.88
3.45
30
35
SHC
IP
TC
SHC
3.99
1.51
4.91
3.82
5.30
4.17
1.54
5.40
4.01
4.33
1.57
5.88
4.16
30
35
SHC
IP
TC
SHC
4.74
2.02
5.84
4.54
6.30
4.96
2.06
6.41
4.77
5.14
2.10
6.99
4.95
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE
Outdoor Temp. (°C)
40
IP
TC
SHC
1.35
3.79
3.05
1.44
1.37
1.38
4.17
3.20
1.47
1.40
4.54
3.33
1.50
Outdoor Temp. (°C)
40
IP
TC
SHC
1.63
4.57
3.67
1.74
1.65
1.66
5.02
3.86
1.77
1.69
5.47
4.01
1.80
Outdoor Temp. (°C)
40
IP
TC
SHC
2.18
5.43
4.37
2.33
2.21
2.22
5.97
4.59
2.37
2.26
6.50
4.77
2.42
103
46
IP
TC
SHC
IP
3.45
2.90
1.56
3.79
3.05
1.59
4.13
3.18
1.62
46
IP
TC
SHC
IP
4.16
3.49
1.88
4.56
3.67
1.91
4.97
3.83
1.95
46
IP
TC
SHC
IP
4.94
4.15
2.51
5.42
4.37
2.56
5.91
4.55
2.61
Indoor 27°C/19°C
Outdoor 35°C/24°C