13. DDC Instruction
General
DDC Data Re-programming
In case the main EEPROM with Software DDC which store all factory settings were replaced because of defect,
repaired monitor' the serial numbers have to be re-programmed.
It is advised to re- soldered the main EEPROM with Software DDC from the old board onto the new board if circuit
board have been replaced, in this case the DDC data does not need to be re-programmed.
Additional information about DDC (Display Data Channel) may be obtained from Video Electronics Standards
Association (VESA). Extended Display Identification Data (EDID) information may be also obtained from VESA.
1. An i486 (or above) personal computer or compatible.
2. Microsoft operation system Windows 95/98/2000/XP.
3. "PORT95NT.exe, WinDDC.exe" program.
4. Software OSD SN Alignment kits
The kit contents:
a. OSD SN BOARD x1
b. Printer cablex1
c. VGA cable x 1
d. 12V DC power source
13.1. Install the "PORT95NT.EXE", and restart the computer.
The process of installing "PORT95NT" has been specified in, so it will not be specified again. If you have any
problem, please read it.
13.2 Connect the DDC Board as follow:
When you write analog
EDID, Connect this port
to the Philips model VGA
port
Note: Cut off the 5th pin of the analog connector, as follow:
Meridian 1
Connect to the
PC LPT
12V Input
49