Condensate Change; Filling Valve Maintenance - Bauer Junior II-B-F01 Instruction Manual

Junior ii series
Table of Contents

Advertisement

Instruction Manual w Junior II
alent to between 10 and 13 operating hours at a filling pres­
sure of 200 bar.
The longer service life of the cartridge at a
filling pressure of 300 bar is annihilated by
the larger volume of filled air per bottle,
therefore the possible number of bottle fillings stays
the same at different pressures.
CARTRIDGE CHANGE
For safety reasons only CO removal
WARNING
cartridges part no. 059183 should
be used on compressor units with
petrol engine. On units with electric engine either CO
removal cartridge part no. 059183 or TRIPLEX car­
tridge part no. 057679 can be used.
Units with petrol engine are delivered with
CO removal cartridge part no. 059183 as
standard, units with electric engine with
TRIPLEX cartridge part no. 057679. When changing
from electric engine to a petrol engine also replace car­
tridge part no. 057679 with cartridge part no. 059183.
Never remove replacement cartridge from
packaging prior to actual use otherwise
highly sensitive molecular sieve will ab­
sorb water vapour from surrounding air and cartridge
saturated and thus be ruined.
-
Prior to changing the filter cartridge, drain condensate
and depressurize filter system completely by opening
condensate drain valves.
-
Remove filter head (3, Fig. 29).
-
Extract old cartridge and insert a new one.
-
Screw in filter head to the stop without use of force.
The used cartridge must be disposed of ac­
cording to local regulations.

FILLING VALVE MAINTENANCE

To protect filling valve against contamination a sintered
metal filter is screwed in the filling valve body.
Remove filter insert and clean, if heavily soiled replace, as fol­
lows (refer to maintenance schedule, 4.3.):
-
Unscrew pressure gauge from filling valve body.
-
Screw off sintered metal filter with a suitable screw driver.
-
To clean filter element, the best method is to use hot
soapy water and to blow dry with compressed air. Re­
place if heavily soiled.
-
Screw in filter element,.
-
Seal pressure gauge with PTFE tape or Loctite 243 and
screw in tight to desired position.